English
Language : 

HCC4046B Datasheet, PDF (6/13 Pages) STMicroelectronics – MICRMICROPOWER PHASE-LOCKED LOOP _
HCC/HCF4046B
STATIC ELECTRICAL CHARACTERISTICS (continued)
Test Conditions
Value
Symbol Parameter
VI
VO |IO | VD D
T Lo w*
25°C
T High*
(V) (V) (µA) (V) Min. Max. Min. Typ. Max. Min. Max.
IOL
Output
Sink
Current
0/ 5 0.4
HCC
Types
0/10
0.5
0/15 1.5
5 0.64
0.51 1
0.36
10 1.6
1.3 2.6
0.9
15 4.2
3.4 6.8
2.4
0/ 5 0.4
HCF
Types
0/10
0.5
0/15 1.5
5 0.52
0.44 1
0.36
10 1.3
1.1 2.6
0.9
15 3.6
3.0 6.8
2.4
VIH Input High
0.5/4.5 < 1 5 3.5
3.5
3.5
Voltage
1/9 < 1 10 7
7
7
1.5/13.5 < 1 15 11
11
11
VIL Input Low
Voltage
4.5/0.5 < 1 5
1.5
9/1 < 1 10
3
1.5
1.5
3
3
13.5/1.5 < 1 15
4
4
4
I IH, IIL
Input
Leakage
Current
HCC 0/18
Types
Any Input
18
± 0.1
± 10– 5 ± 0.1
±1
(except.
pin 14)
HCF
Types 0/15
15
± 0.3
± 10– 5 ± 0.3
±1
IOUT
3-state
Leakage
Current
HCC
Types 0/18
HCF
Types 0/15
0/18
0/15
18
± 0.4
± 10– 4 ± 0.4
± 12
15
± 1.0
± 10– 4 ± 1.0
± 7.5
CI Input Capacitance
Any Input
5 7.5
* TLow = – 55°C for HCC device : – 40°C for HCF device.
* THigh = + 125°C for HCC device : + 85°C for HCF device.
The Noise Margin for both ”1” and ”0” level is : 1V min. with VDD = 5V, 2V min. with VDD = 10V, 2.5V min. with VDD = 15V.
Unit
mA
V
V
µA
µA
pF
6/13