English
Language : 

TL1431_05 Datasheet, PDF (5/13 Pages) STMicroelectronics – Programmable Voltage Reference
TL1431
Electrical Characteristics
Table 4.
Symbol
Tamb = 25°C (unless otherwise specified)
Parameter
TL1431I
TL1431AI
Unit
Min. Typ. Max. Min. Typ. Max.
Reference Input Voltage - figure 1
Vref
VKA = Vref , Ik = 10 mA
V
2.490 2.500 2.510 2.493 2.500 2.507
∆Vref
Reference Input Voltage Deviation Over
Temperature Range (1) - figure 1
VKA = Vref, Ik = 10 mA, Tmin ≤Tamb ≤ Tmax
7 30
mV
7 30
∆----V-----r--e----f
∆T
Temperature Coefficient of Reference Input
Voltage (2)
VKA = Vref, Ik = 10 mA, Tmin ≤Tamb ≤ Tmax
±22 ±100
ppm/°C
±22 ±100
∆-∆---V-V----rk--e--a--f
Ratio of Change in Reference Input Voltage to
Change in Cathode to Anode Voltage - figure 2
Ik = 10mA - ∆VKA = 36V to 3V
-1.1 2
mV/V
-1.1 2
Reference Input Current
Iref Ik = 10mA, R1 = 10kΩ, R2 = ∞
Tmin ≤Tamb ≤Tmax
1.5 2.5
3
1.5 2.5 µA
3
Reference Input Current Deviation Over
Temperature Range
∆Iref
Ik = 10mA, R1 = 10kΩ, R2 =∞
Tmin ≤Tamb ≤ Tmax
0.5 1
µA
0.8 1.2
Minimum Cathode Current for Regulation - figure 1
Imin
VKA = Vref
0.5 1
mA
0.5 0.7
Ioff
⏐ZKA⏐
Off-State Cathode Current - figure 3
Dynamic Impedance (3)
VKA = Vref , ∆ Ik = 1 to100mA, f ≤1kHZ
180 500
0.2 0.5
180 500 nA
Ω
0.2 0.5
1. ∆Vref is defined as the difference between the maximum and minimum values obtained over the full temperature range.
∆Vref = Vref max. - Vref min.
V ref max.
V ref min.
T1
T2
Temperature
2. The temperature coefficient is defined as the slopes (positive and negative) of the voltage vs temperature limits within
which the reference is guaranteed.
3. The dynamic Impedance is definied as|ZKA| =
Max
-n ppm/°C +n ppm/°C
2.5V
min
Temperature
25°C
∆-----V----K-----A--
∆IK
5/13