English
Language : 

STM8L101 Datasheet, PDF (44/81 Pages) STMicroelectronics – 8-bit ultralow power microcontroller with up to 8 Kbytes Flash multifunction timers, comparators, USART, SPI, I2C
Electrical parameters
STM8L101xx
Table 20.
Symbol
Total current consumption and timing in Halt and Active-halt mode at
VDD = 1.65 V to 3.6 V (1)(2)
Parameter
Conditions
Typ Max Unit
TA = -40 °C to 25 °C 0.8 2 μA
IDD(AH)
Supply current in Active-halt
mode
LSI RC osc.
(at 37 kHz)
TA = 55 °C
TA = 85 °C
TA = 105 °C
1 2.5 μA
1.4 3.2 μA
2.9 7.5 μA
TA = 125 °C
5.8 13 μA
Supply current during
IDD(WUFAH) wakeup time from Active-halt
mode
2
- mA
tWU(AH)(3)
Wakeup time from Active-
halt mode to Run mode
fCPU= 16 MHz
IDD(Halt)
IDD(WUFH)
TA = -40 °C to 25 °C
TA = 55 °C
Supply current in Halt mode TA = 85 °C
TA = 105 °C
TA = 125 °C
Supply current during
wakeup time from Halt mode
4 6.5 μs
0.35 1.2(4) μA
0.6 1.8 μA
1 2.5(4) μA
2.5 6.5 μA
5.4 12(4) μA
2
- mA
tWU(Halt)(3)
Wakeup time from Halt mode
to Run mode
fCPU = 16 MHz
4 6.5 μs
1. TA = -40 to 125 °C, no floating I/O, unless otherwise specified.
2. Data based on characterization results, not tested in production.
3. Measured from interrupt event to interrupt vector fetch.
To get tWU for another CPU frequency use tWU(FREQ) = tWU(16 MHz) + 1.5 (TFREQ-T16 MHz).
The first word of interrupt routine is fetched 5 CPU cycles after tWU.
4. Data guaranteed, each individual device tested in production.
Figure 15. Typ. IDD(Halt) vs. VDD, fCPU = 2 MHz and 16 MHz
7
6
-40°C
5
25°C
4
85°C
125°C
3
2
1
0
1.6
2.1
2.6
3.1
3.6
VDD [V]
1. Typical current consumption measured with code executed from Flash.
ai17014b
44/81
Doc ID 15275 Rev 11