English
Language : 

TL072_07 Datasheet, PDF (4/16 Pages) STMicroelectronics – Low noise J-FET dual operational amplifiers
Absolute maximum ratings and operating conditions
TL072 - TL072A - TL072B
2
Absolute maximum ratings and operating conditions
Table 1. Absolute maximum ratings
Symbol
Parameter
TL072M, AM,
BM
VCC
Vi
Vid
Ptot
Rthja
Supply voltage (1)
Input voltage (2)
Differential input voltage (3)
Power dissipation
Thermal resistance junction to ambient(4)
SO-8
DIP8
Rthjc
Thermal resistance junction to case
SO-8
DIP8
Output short-circuit duration (5)
Tstg
ESD
Storage temperature range
HBM: human body model(6)
MM: machine model(7)
CDM: charged device model(8)
TL072I, AI, BI
±18
±15
±30
680
125
85
40
41
Infinite
-65 to +150
1
200
1500
TL072C, AC,
BC
Unit
V
V
V
mW
°C/W
°C/W
°C
kV
V
V
1. All voltage values, except differential voltage, are with respect to the zero reference level (ground) of the supply voltages
where the zero reference level is the midpoint between VCC+ and VCC-.
2. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 volts, whichever is less.
3. Differential voltages are the non-inverting input terminal with respect to the inverting input terminal.
4. Short-circuits can cause excessive heating. Destructive dissipation can result from simultaneous short-circuit on all
amplifiers.
5. The output may be shorted to ground or to either supply. Temperature and/or supply voltages must be limited to ensure
that the dissipation rating is not exceeded.
6. Human body model: 100pF discharged through a 1.5kΩ resistor between two pins of the device, done for all couples of pin
combinations with other pins floating.
7. Machine model: a 200pF cap is charged to the specified voltage, then discharged directly between two pins of the device
with no external series resistor (internal resistor < 5Ω), done for all couples of pin combinations with other pins floating.
8. Charged device model: all pins plus package are charged together to the specified voltage and then discharged directly to
the ground.
Table 2. Operating conditions
Symbol
Parameter
TL072M, AM,
BM
TL072I, AI, BI
TL072C, AC,
BC
Unit
VCC
Supply voltage
6 to 36
V
Toper
Operating free-air temperature range -55 to +125 -40 to +105
0 to +70
°C
4/16