English
Language : 

LCP02-150M Datasheet, PDF (4/10 Pages) STMicroelectronics – PROGRAMMABLE TRANSIENT VOLTAGE SUPPRESSOR FOR RINGING SLICS
Characteristics
LCP02-150M
Table 5. Electrical parameters related to the negative suppressor
Symbol
Test conditions
Min.
Max.
Unit
IGN
IH-
IRGL-
VDGL-
VGN/GND = -60 V
Measured at 50 Hz
Go No-Go test, VGN = -60 V
Tj = 25° C, VGN/line = -190 V
VGN/GND = -60V
10/1000 µs 1 kV RP = 25 Ω IPP = 30 A
10/700 µs 2 kV RP = 25 Ω IPP = 30 A
1.2/50 µs 2 kV RP = 25 Ω IPP = 30 A
5
mA
150
mA
5
µA
10
6
V
12
Table 6. Electrical parameters related to the positive suppressor
Symbol
Test conditions
Min.
Max.
Unit
IGP
VGP/GND = 60 V
Measured at 50 Hz
IRGL+
VDGL+
Tj = 25° C, VGP/line = +190 V
VGP/GND = +60V
10/1000 µs 1 kV RP = 25 Ω IPP = 30 A
10/700 µs 2 kV RP = 25 Ω IPP = 30 A
1.2/50 µs 2 kV RP = 25 Ω IPP = 30 A
10
mA
5
µA
12
8
V
18
Table 7.
Symbol
Electrical parameters related to line/gnd
Test conditions
Typ.
Max.
Unit
IR
Tj = 25° C, VLINE = +90 V, VGP/LINE = +1 V
Tj = 25° C, VLINE = -105 V, VGN/LINE = -1 V
Coff VR = -3 V, F =1 MHz, VGP = 60 V, VGN = -60 V
5
5
µA
150
pF
4/10