UM1657 Datasheet, PDF (33/48 Pages) STMicroelectronics – SPIRIT1 development kit
UM1657
SPIRIT1 DK - GUI description
Using this packet setting, the transmitter builds the frame with a length field of one byte, and
then adds the data blocks with CRC included. The GUI shows the frame received with the
length field and the CRC field for each data blocks.
Figure 21. Packet setting panel (MBUS Packet view)
3.3
Transmission test
Selecting the "Transmission test" view, the user has all the controls to access the packet
tests available until now to run transmission
Figure 22. Transmission test panel
DocID025094 Rev 1
33/48
48