English
Language : 

GS-BT2416C1.AT1 Datasheet, PDF (30/38 Pages) STMicroelectronics – Bluetooth® class 1 module with embedded SPP SW
AT command
GS-BT2416C1.AT1
A.26
AT+UARTSETUP
Set the local UART settings. The changes take affect immediately after the OK response. It
is advisable to issue an AT command after the AT+UARTSETUP in order to make sure the
MCU is synchronized up correctly with the new settings. The new settings are used both for
the COMMAND MODE and DATA MODE. Use the command AT+BTMACROSTART to store
a startup setting for the UART. Is not allowed to use AT+UARTSETUP command in a macro!
Due to internal time needed to write a flash memory area a little time delay is possible
before any return value.
Syntax: AT+UARTSETUP=BaudRate, DataBits, Parity, Stopbits, Fc
Parameters:
Baud Rate: UART baud rate in bps. Possible values are: 300, 1200, 2400, 4800,
9600 (default), 19200, 38400, 57600, 115200, 153600, 230400, 460800.
DataBits: possible values are 5, 6, 7, 8 (default)
) Parity: possible values are None (default), Even, Odd
t(s StopBits: possible values are 1 (default), 2
c Fc: flow control. Possible values are None (default), Hardware
du Return value: <OK, ERROR>
Obsolete Pro A.27
AT+UARTSETUP=?
Output the current UART configuration settings. The command generates an +UARTSETUP
message with the configuration parameters of the module’s UART. For the parameters list,
see the AT+UARTSETUP command.
t(s) - Syntax: AT+UARTSETUP=?
c Return value: +UARTSETUP, <OK, ERROR>
te Produ A.28
AT+VER
Requests the ID, version number and revision date of the firmware. The command
generates a +VER event.
sole Syntax: AT+VER
Ob Return value: +VER, <OK, ERROR>
30/38