VN05H Datasheet, PDF (3/10 Pages) STMicroelectronics – HIGH SIDE SMART POWER SOLID STATE RELAY
VN05H
THERMAL DATA
Rthj-case Thermal Resistance Junction-case
Rthj-amb Thermal Resistance Junction-ambient
Max
Max
2.4
62.5
oC/W
oC/W
ELECTRICAL CHARACTERISTICS (VCC = 9 to 36 V; -40 ≤ Tj ≤ 125 oC unless otherwise specified)
POWER
Symbol
VCC
Ron
Parameter
Supply Voltage
On State Resistance
IS
Supply Current
Test Conditions
see note 1
IOUT = 6 A
IOUT = 6 A
Off State
On State
Tj = 25 oC
Tj ≥ 25 oC
Min.
5.5
Typ.
13
Max.
36
0.18
0.36
50
15
Unit
V
Ω
Ω
µA
mA
SWITCHING
Symbol
td(on)
tr
td(off)
tf
(di/dt)on
(di/dt)off
Vdemag
Parameter
Test Conditions
Turn-on Delay Time Of
Output Current
Rise Time Of Output
Current
Turn-off Delay Time Of
Output Current
Fall Time Of Output
Current
Turn-on Current Slope
IOUT = 6 A Resistive Load
Input Rise Time < 0.1 µs Tj = 25 oC
IOUT = 6 A Resistive Load
Input Rise Time < 0.1 µs Tj = 25 oC
IOUT = 6 A Resistive Load
Input Rise Time < 0.1 µs Tj = 25 oC
IOUT = 6 A Resistive Load
Input Rise Time < 0.1 µs Tj = 25 oC
IOUT = 6 A
IOUT = IOV 25 ≤ Tj ≤ 140 oC
Turn-off Current Slope IOUT = 6 A
IOUT = IOV 25 ≤ Tj ≤ 140 oC
Inductive Load Clamp IOUT = 6 A L = 1 mH
Voltage
Min.
-7
Typ.
15
30
20
10
-4
Max.
0.5
2
2
4
-2
Unit
µs
µs
µs
µs
A/µs
A/µs
A/µs
A/µs
V
LOGIC INPUT
Symbol
VIL
VIH
VI(hyst.)
IIN
VICL
Parameter
Input Low Level
Voltage
Input High Level
Voltage
Input Hysteresis
Voltage
Input Current
Input Clamp Voltage
Test Conditions
VIN = 5 V
IIN = 10 mA
IIN = -10 mA
Min.
Typ.
Max.
0.8
Unit
V
2
(*)
V
0.5
V
50
µA
6
V
-0.7
V
3/10