Absolute maximum ratings and operating conditions
Absolute maximum ratings and operating conditions
Table 1. Absolute maximum ratings
Symbol
Parameter
Value
Unit
TL084M, AM, BM TL084I, AI, BI TL084C, AC, BC
VCC
Vi
Vid
Rthja
Supply voltage (1)
Input voltage (2)
Differential input voltage (3)
Thermal resistance junction to
ambient(4) (5)
SO-14
DIP14
TSSOP14
±18
V
±15
V
±30
V
105
°C/W
80
100
Rthjc
Thermal resistance junction to
case(4) (5)
SO-14
DIP14
TSSOP14
31
°C/W
33
32
Ptot Power dissipation
Output short-circuit duration (6)
680
mW
Infinite
Toper Operating free-air temperature range
-55 to +125
-40 to +105
0 to +70
°C
Tstg Storage temperature range
HBM: human body model(7)
-65 to +150
°C
1000
ESD MM: machine model(8)
150
V
CDM: charged device model(9)
1500
1. All voltage values, except differential voltage, are with respect to the zero reference level (ground) of the supply voltages
where the zero reference level is the midpoint between VCC+ and VCC-.
2. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 volts, whichever is less.
3. Differential voltages are the non-inverting input terminal with respect to the inverting input terminal.
4. Short-circuits can cause excessive heating and destructive dissipation.
5. Rth are typical values.
6. The output may be shorted to ground or to either supply. Temperature and/or supply voltages must be limited to ensure
that the dissipation rating is not exceeded.
7. Human body model: 100pF discharged through a 1.5kΩ resistor between two pins of the device, done for all couples of pin
combinations with other pins floating.
8. Machine model: a 200pF cap is charged to the specified voltage, then discharged directly between two pins of the device
with no external series resistor (internal resistor < 5Ω), done for all couples of pin combinations with other pins floating.
9. Charged device model: all pins plus package are charged together to the specified voltage and then discharged directly to
the ground.
Table 2.
Symbol
Operating conditions
Parameter
TL084M, AM, BM TL084I, AI, BI TL084C, AC, BC Unit
VCC Supply voltage range
6 to 36
V
Toper Operating free-air temperature range
-55 to +125
-40 to +105
0 to +70
°C
3/16