English
Language : 

TL072CDT Datasheet, PDF (3/16 Pages) STMicroelectronics – Low noise JFET dual operational amplifiers
TL072, TL072A, TL072B
Absolute maximum ratings and operating conditions
2
Absolute maximum ratings and operating conditions
Table 1. Absolute maximum ratings
Symbol
Parameter
TL072I, AI, BI
TL072C, AC,
BC
Unit
VCC
Vin
Vid
Rthja
Rthjc
Supply voltage (1)
Input voltage (2)
Differential input voltage (3)
Thermal resistance junction to ambient(4)
SO-8
DIP8
Thermal resistance junction to case (4)
SO-8
DIP8
Output short-circuit duration (5)
±18
±15
±30
125
85
40
41
Infinite
V
V
V
°C/W
°C/W
Tstg
ESD
Storage temperature range
HBM: human body model(6)
MM: machine model(7)
CDM: charged device model(8)
-65 to +150
°C
1
kV
200
V
1.5
kV
1. All voltage values, except differential voltage, are with respect to the zero reference level (ground) of the
supply voltages where the zero reference level is the midpoint between VCC+ and VCC-.
2. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 volts,
whichever is less.
3. Differential voltages are the non-inverting input terminal with respect to the inverting input terminal.
4. Short-circuits can cause excessive heating. Destructive dissipation can result from simultaneous short-
circuits on all amplifiers.
5. The output may be shorted to ground or to either supply. Temperature and/or supply voltages must be
limited to ensure that the dissipation rating is not exceeded.
6. Human body model: 100 pF discharged through a 1.5 kΩ resistor between two pins of the device, done for
all couples of pin combinations with other pins floating.
7. Machine model: a 200 pF cap is charged to the specified voltage, then discharged directly between two
pins of the device with no external series resistor (internal resistor < 5 Ω). This is done for all couples of pin
combinations with other pins floating.
8. Charged device model: all pins plus package are charged together to the specified voltage and then
discharged directly to the ground.
Table 2. Operating conditions
Symbol
Parameter
TL072I, AI, BI
TL072C, AC,
BC
Unit
VCC
Supply voltage
6 to 36
V
Toper
Operating free-air temperature range -40 to +105
0 to +70
°C
Doc ID 2298 Rev 7
3/16