English
Language : 

TL071_07 Datasheet, PDF (3/13 Pages) Texas Instruments – LOW-NOISE JFET-INPUT OPERATIONAL AMPLIFIERS
TL071
2
Absolute maximum ratings and operating conditions
Absolute maximum ratings and operating conditions
Table 1. Absolute maximum ratings
Symbol
Parameter
Value
Unit
TL071M, AM, BM TL071I, AI, BI TL071C, AC, BC
VCC
Vi
Vid
Ptot
Rthja
Supply voltage (1)
Input voltage (2)
Differential input voltage (3)
Power dissipation
Thermal resistance junction to
ambient(4) (5)
SO-8
DIP8
±18
V
±15
V
±30
V
680
mW
125
°C/W
85
Rthjc
Thermal resistance junction to
case(4) (5)
SO-8
DIP8
Output short-circuit duration (6)
40
41
Infinite
°C/W
Toper Operating free-air temperature range
-55 to +125
-40 to +105
0 to +70
°C
Tstg Storage temperature range
HBM: human body model(7)
-65 to +150
°C
1
kV
ESD MM: machine model(8)
200
V
CDM: charged device model(9)
1500
V
1. All voltage values, except differential voltage, are with respect to the zero reference level (ground) of the supply voltages
where the zero reference level is the midpoint between VCC+ and VCC-.
2. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 volts, whichever is less.
3. Differential voltages are the non-inverting input terminal with respect to the inverting input terminal.
4. Short-circuits can cause excessive heating. Destructive dissipation can result from simultaneous short-circuits on all
amplifiers.
5. Rth are typical values.
6. The output may be shorted to ground or to either supply. Temperature and/or supply voltages must be limited to ensure
that the dissipation rating is not exceeded.
7. Human body model: 100pF discharged through a 1.5kΩ resistor between two pins of the device, done for all couples of pin
combinations with other pins floating.
8. Machine model: a 200pF cap is charged to the specified voltage, then discharged directly between two pins of the device
with no external series resistor (internal resistor < 5Ω), done for all couples of pin combinations with other pins floating.
9. Charged device model: all pins plus package are charged together to the specified voltage and then discharged directly to
the ground.
Table 2. Operating conditions
Symbol
Parameter
TL071M, AM,
BM
TL071I, AI, BI
TL071C, AC,
BC
Unit
VCC
Supply voltage
6 to 36
V
Toper
Operating free-air temperature range -55 to +125 -40 to +105
0 to +70
°C
3/13