English
Language : 

SN75276 Datasheet, PDF (3/16 Pages) STMicroelectronics – FAIL-SAFE DIFFERENTIAL BUS TRANSCEIVER
SN75276
FAIL-SAFE DIFFERENTIAL BUS TRANSCEIVER
schematics of inputs and outputs
SLLS212B – SEPTEMBER 1995 – REVISED APRIL 1998
EQUIVALENT OF EACH INPUT
VCC
R(eq)
Input
TYPICAL OF A AND B I/O PORTS
VCC
180 kΩ
NOM
Connected
on A Port
A or B
18 kΩ
NOM
3 kΩ
NOM
TYPICAL OF RECEIVER OUTPUT
VCC
85 Ω
NOM
Output
Driver input: R(eq) = 3 kΩ NOM
Enable inputs: R(eq) = 8 kΩ NOM
R(eq) = equivalent resistor
180 kΩ
NOM
Connected
on B Port
1.1 kΩ
NOM
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Voltage at any bus terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 10 V to 15 V
Enable input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values, except differential input/output bus voltage, are with respect to network ground terminal.
PACKAGE
D
P
DISSIPATION RATING TABLE
TA ≤ 25°C
POWER RATING
725 mW
DERATING FACTOR
ABOVE TA = 25°C
5.8 mW/°C
TA = 70°C
POWER RATING
464 mW
1100 mW
8.8 mW/°C
704 mW
TA = 105°C
POWER RATING
261 mW
396 mW
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265