English
Language : 

STCN75 Datasheet, PDF (29/35 Pages) STMicroelectronics – Digital temperature sensor and thermal watchdog
STCN75
Figure 15. Bus timing requirements sequence
DC and AC parameters
SDA
tBUF
SCL
P
tHD:STA
tR
tF
tHIGH
S
tLOW
tSU:DAT
tHD:DAT
tHD:STA
tSU:STA
SR
tSU:STO
P
AI00589
Table 13. AC characteristics
Sym
Parameter(1)
Min Max Unit
fSCL SCL clock frequency
tBUF Time the bus must be free before a new transmission can start
tF
SDA and SCL fall time
tHD:DAT(2) Data hold time
tHD:STA
START condition hold time
(after this period the first clock pulse is generated)
0 400 kHz
1.3
µs
300 ns
0
µs
600
ns
tHIGH
tLOW
tR
tSU:DAT
tSU:STA
Clock high period
Clock low period
SDA and SCL rise time
Data setup time
START condition setup time
(only relevant for a repeated start condition)
600
ns
1.3
µs
300 ns
100
ns
600
ns
tSU:STO STOP condition setup time
600
ns
1. Valid for ambient operating temperature: TA = –55 to 125°C; VDD = 2.7V to 5.5V (except where noted).
2. Transmitter must internally provide a hold time to bridge the undefined region (300ns max) of the falling
edge of SCL
29/35