UM1481 Datasheet, PDF (28/55 Pages) STMicroelectronics – This document describes an easy and compact solution
Graphical user interface application
Figure 34. Board connected
UM1481
To start evaluating board parameters and its configuration, the user must first connect the
board to a USB port using the USB micro-B cable and then connect the GUI using the
connect tab. When the board is connected properly to the GUI, it shows the message “The
board is connected”, as shown in Figure 34.
6.3
Key battery parameters
The following are the parameters that appear on the first page (key parameter page) of the
GUI, as shown in Figure 35.
● Board hardware: it is possible to read and write the value of the sense resistor as well
as the room temperature value.
● Alarm: it is possible to R/W the battery low voltage alarm as well as the low SOC alarm.
● Battery parameters: it is possible to read and write total battery capacity, internal
resistance of the battery pack as well as the open circuit voltage and its relative SOC
percentage table to be used for an estimation of initial SOC of battery depending on the
open circuit voltage.
● Control register: it is possible to read the value of the control register as well as write
the 1st bit (bit 0) of this register.
● Mode register: it is possible to read the value of the mode register as well as write the
3rd and 4th bits (bit 2 and 3).
28/55
Doc ID 022389 Rev 1