English
Language : 

RX95HF Datasheet, PDF (26/44 Pages) STMicroelectronics – Near field communication transceiver for tag emulation
Commands
RX95HF
Table 25. AC filter command description (Command <Len> = 0x00)
Direction
Data
Comments
Example
Host to
RX95HF
0D
<Len>
00
RX95HF to 01
Host
yy
RX95HF to 82
Host
00
Command code
Length of data (0x00)
Result code
Length of data
Tag Emulator state
Error code
Length of data
If <Len> = 0x00, AC filter is deactivated
and response will return Tag Emulation
state.
>>>0x0D00 Deactivate AC Filter
AC filter is deactivated and response will
return Tag Emulation state.
<<<0x0001yy
where yy is the Tag Emulation state
(Table 28).
<<<0x8200
Invalid command length
Table 26. AC filter command description (Command <Len> = 0x01)
Direction
Data
Comments
Example
Host to
RX95HF
0D
<Len>
yy
Command code
Length of data (0x01)
Tag Emulator state
If <Len> = 0x01, AC Filter state will be
forced to yy state (Table 28).
>>>0x0D01yy Force new Tag
Emulation state (yy).
00
RX95HF to
Host
00
RX95HF to 82
Host
00
Result code
Length of data
Error code
Length of data
If <Len> = 0x01, Tag Emulation state is
successfully set.
<<<0x0000
<<<0x8200
Invalid command length
Table 27. AC filter command description (Command <Len> = 0x02)
Direction
Data
Comments
Example
Host to
RX95HF
0D
<Len>
0000
00
RX95HF to
Host
01
yy
RX95HF to 82
Host
00
Command code
Length of data (0x02)
ST Reserved
Result code
Length of data
Tag Emulator state
Error code
Length of data
If <Len> = 0x02, response will return
Tag Emulation state without de-
activating the AC filter.
>>>0x0D020000
If <Len> = 0x02, returns Tag Emulation
state (Table 28) without de-activating
the AC filter.
<<<0x0001yy
<<<0x8200
Invalid command length
26/44
DocID023884 Rev 3