English
Language : 

M41T66 Datasheet, PDF (25/33 Pages) STMicroelectronics – Serial access real-time clock with alarms
M41T66
DC and AC parameters
Table 9. Capacitance
Symbol
Parameter(1)(2)
Min Max Unit
CIN
COUT(3)
Input capacitance
Output capacitance
tLP
Low-pass filter input time constant (SDA and SCL)
1. Effective capacitance measured with power supply at 3.6 V; sampled only, not 100% tested.
2. At 25°C, f = 1 MHz.
3. Outputs deselected.
7
pF
10
pF
50
ns
Table 10. DC characteristics
Sym
Parameter
Test condition(1)
Min Typ Max Unit
0°C to 85°C
1.0
4.4
V
VCC(2) Operating voltage
Clock
–20°C to 85°C 1.3
–40°C to 85°C 1.5
I2C bus (400 kHz)
1.3
4.4
V
4.4
V
4.4
V
4.4 V
100 µA
ICC1 Supply current
SCL = 400 kHz
(no load)
3.6 V
3.0 V
2.5 V
50
70
µA
35
µA
30
µA
2.0 V
20
µA
ICC2 Supply current (standby)
SCL = 0 Hz
all inputs
SQW off
≥ VCC – 0.2 V
≤ VSS + 0.2 V
4.4 V
3.6 V
3.0 V at 25°C
1.8 V at 25°C
1100 nA
550 900 nA
525
nA
450
nA
VIL Input low voltage
VIH Input high voltage
VOL Output low voltage
VCC = 4.4 V, IOL = 1.0 mA
(SQW, IRQ/OUT)
–0.2
0.7VCC
0.3 VCC V
VCC+0.3 V
0.4
V
VPU
Pull-up supply voltage
(open drain)
ILI Input leakage current
ILO Output leakage current
Square wave duty cycle(3)
IRQ/OUT
SQW
0V ≤ VIN ≤ VCC
0V ≤ VOUT ≤ VCC
No load
4.4
V
VCC
V
±1 µA
±1 µA
40 50
60
%
1. Valid for ambient operating temperature: TA = –40 to 85°C; VCC = 1.5 V to 4.4 V (except where noted).
2. Oscillator startup guaranteed at 1.6 V only at 25°C.
3. Guaranteed by design.
25/33