English
Language : 

THS9001_08 Datasheet, PDF (2/20 Pages) STMicroelectronics – 50 MHz to 350 MHz CASCADEABLE AMPLIFIER
THS9001
SLOS426B – NOVEMBER 2003 – REVISED JANUARY 2007
www.ti.com
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
PACKAGED DEVICES(1)
THS9001DBVT
THS9001DBVR
AVAILABLE OPTIONS
PACKAGE TYPE
SOT-23-6
TRANSPORT MEDIA, QUANTITY
Tape and Reel, 250
Tape and Reel, 3000
(1) For the most current package and ordering information, see the Package Option Addendum at the end
of this document, or see the TI Web site at www.ti.com.
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature (unless otherwise noted)(1)
VSS Supply voltage, GND to VS
VI
Input voltage
Continuous power dissipation
TJ
Maximum junction temperature
TJ
Maximum junction temperature, continuous operation, long term reliability (2)
Tstg Storage temperature
HBM
ESD Ratings
CDM
MM
UNIT
5.5 V
GND to VS
See Dissipation Ratings
Table
150°C
125°C
-65°C to 150°C
2000
1500
100
(1) The absolute maximum ratings under any condition is limited by the constraints of the silicon process. Stresses above these ratings may
cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are
stress ratings only, and functional operation of the device at these or any other conditions beyond those specified is not implied.
(2) The maximum junction temperature for continuous operation is limited by package constraints. Operation above this temperature may
result in reduced reliability and/or lifetime of the device.
DISSIPATION RATING TABLE
PACKAGE
DBV (2)
ΘJC
(°C/W)
70.1
ΘJA
(°C/W)
216
TA≤ 25°C
463 mW
POWER RATING(1)
TA = 85°C
185 mW
(1) Power rating is determined with a junction temperature of 125°C. Thermal management of the final PCB should strive to keep the
junction temperature at or below 125°C for best performance.
(2) This data was taken using the JEDEC standard High-K test PCB.
RECOMMENDED OPERATING CONDITIONS
VSS
Supply voltage
TA
Operating free-air temperature,
IS
Supply current
MIN
NOM
MAX UNIT
2.7
5
V
-40
85
°C
100
mA
2
Submit Documentation Feedback