English
Language : 

AN3028 Datasheet, PDF (19/37 Pages) M/A-COM Technology Solutions, Inc. – ESD Protection of Broadband GaAs CATV & FTTx Amplifiers
AN3028
Burst mode and output voltage ripple
Figure 22. ENERGY STAR® efficiency criteria
The power supply presented is from a standard model and, in order to be compliant with the
ENERGY STAR® requirements, needs to have efficiency higher than 71.6%. If the self-
supply is excluded, the efficiency results (seeTable 9) are higher than the recommended
value within the whole input voltage range.
6.2
Light-load performance
The input power of the converter has been measured in no-load condition for different input
voltages and the results are given in Table 12.
Table 12. No-load input power
VIN_AC (VRMS)
90
115
150
180
230
265
Without
self-supply
21
22
25
26
29
32
PIN (mW)
With
self-supply
88
110
146
175
224
258
Doc ID 16135 Rev 1