English
Language : 

TDA7564 Datasheet, PDF (16/20 Pages) STMicroelectronics – MULTIFUNCTION QUAD POWER AMPLIFIER WITH BUILT-IN DIAGNOSTICS FEATURES
TDA7564
If R/W = 1, the TDA7564 sends 4 "Diagnostics Bytes" to µP: DB1, DB2, DB3 and DB4.
DB1
D7
Thermal warning active (D7 = 1)
D6
Diag. cycle not activated or not terminated (D6 = 0)
Diag. cycle terminated (D6 = 1)
Channel LF
D5
current detection
Output peak current < 250mA - Open load (D5 = 1)
Output peak current > 500mA - Open load (D5 = 0)
Channel LF
D4
Turn-on diagnostic (D4 = 0)
Permanent diagnostic (D4 = 1)
Channel LF
D3
Normal load (D3 = 0)
Short load (D3 = 1)
Channel LF
Turn-on diag.: No open load (D2 = 0)
D2
Open load detection (D2 = 1)
Offset diag.: No output offset (D2 = 0)
Output offset detection (D2 = 1)
Channel LF
D1
No short to Vcc (D1 = 0)
Short to Vcc (D1 = 1)
Channel LF
D0
No short to GND (D1 = 0)
Short to GND (D1 = 1)
DB2
D7
D6
D5
D4
D3
D2
D1
D0
Offset detection not activated (D7 = 0)
Offset detection activated (D7 = 1)
Current sensor not activated (D6 = 0)
Current sensor activated (D6 = 1)
Channel LR
current detection
Output peak current < 250mA - Open load (D5 = 1)
Output peak current > 500mA - Open load (D5 = 0)
Channel LR
Turn-on diagnostic (D4 = 0)
Permanent diagnostic (D4 = 1)
Channel LR
Normal load (D3 = 0)
Short load (D3 = 1)
Channel LR
Turn-on diag.: No open load (D2 = 0)
Open load detection (D2 = 1)
Permanent diag.: No output offset (D2 = 0)
Output offset detection (D2 = 1)
Channel LR
No short to Vcc (D1 = 0)
Short to Vcc (D1 = 1)
Channel LR
No short to GND (D1 = 0)
Short to GND (D1 = 1)
16/20