4.7
Table 10. Receiver characteristics
Parameter
Note Min. Typ. Max. Unit
Sensitivity level for 0.1% BER
-80
dBm
Maximum input power for 0.1% BER
Spurious emission for 30 MHz < f < 1 GHz
-5
dBm
(1)
-57 dBm
Spurious emission f > 1 GHz
(1)
-47 dBm
In band blocking C/I for a wanted signal level of -67 dBm:
– Co-channel interference
– Interference at frequency offset foffs = 1 MHz
– Interference at frequency offset foffs = 2 MHz
– Interference at frequency offset foffs = 3 MHz
– Interference at image frequency foffs = -4 MHz
– Interference at adjacent frequencies to image
21
15
-17 dBm
-27
-9
-15
Out of band blocking for a required signal level of -67 dBm:
– Frequency range 30-1999 MHz
-30
– Frequency range 2000-2399 MHz
-35
dBm
– Frequency range 2484-2999 MHz
-35
– Frequency range 3000-12750 MHz
-30
1. Measuring conditions and signal specifications are described in [3], [4] and [5]. These parameters are
highly related to a correct matching network and PCB design. Refer to Section 8 for design guidelines.
Timing characteristics
Parameter
Table 11. Timing characteristics
Symbol
Conditions
Min. Typ. Max. Unit
Start-up time (power up to
standby mode)
Tstart-up
(1)
-
Sleep => Standby mode
Tsleep_std
(2)
Off => Standby mode
Toff_std
1. This time is dominated by the Xtal oscillator startup.
2. This time is dominated by the Xtal oscillator startup.
- 15.5 -
ms
- 2.6 -
ms
- 2.7 -
ms
DocID022984 Rev 2