English
Language : 

SR1 Datasheet, PDF (14/21 Pages) STMicroelectronics – Integrated test mode
DC and AC parameters
SR1
Symbol
Parameter
Table 4. DC and AC characteristics
Test conditions(1)
Min.
Typ.(2)
Max. Unit
VCC Supply voltage
ICC
Supply current
SR = VCC, tREC and tSRC
counter is not running
2.0
5.5
V
0.4
1.0
µA
VCC  4.5 V, sinking 3.2 mA
0.3
V
VOL Reset output voltage low VCC  3.3 V, sinking 2.5 mA
0.3
V
VCC  2.0 V, sinking 1 mA
0.3
V
tREC
Reset timeout delay,
factory-programmed
(device option)
140
210
280
ms
240
360
480
ms
RPUO
Internal output pull-up
resistor on RST
(device option)
65
k
VRST = 5.5 V, open drain
ILO
Output leakage current device option without output
-0.1
pull-up resistor
0.1
µA
Smart Reset
tSRC
VIL
VIH
RPUI
ILEAK
Smart Reset delay
SR input voltage low
TA = -40 to +85 °C
TA = 25 °C
SR input voltage high
Internal input pull-up
resistor on SR
(device option)
SR input leakage current
device option without input
pull-up resistor
Input glitch immunity
Test mode
0.8 x tSRC
0.9 x tSRC
VSS-0.3
0.85
tSRC(3)
65
1.2 x tSRC
s
1.1 x tSRC
0.3
V
5.5
V
k
-0.1
0.1
µA
tSRC
s
VTEST Test mode entry voltage
tSRC-INI Initial test mode time
tSRC-SHORT
Shortened Smart Reset
delay
VCC +0.9 VCC +1.1 VCC +1.4 V
28
42
56
ms
tSRC / 128
ms
1. Valid for ambient operating temperature TA = -40 to +85 °C, VCC = 2.0 to 5.5 V.
2. Typical values are at 25 °C and VCC = 3.3 V unless otherwise noted.
3. Factory-programmable in the range of 0.5 s to 10 s typ. in 0.5 s steps.
14/21
DocID026048 Rev 2