L9822EPD013TR Datasheet, PDF (12/17 Pages) STMicroelectronics – Octal serial solenoid driver
Functional description
L9822E
4.6
Fault conditions check
Checking for fault conditions may be done in the following way. Clock in a new control byte.
Wait 160 µs or so to allow the outputs to settle.
Clock in the same control byte and observe the diagnostic data that comes out of the device.
The diagnostic bits should be identical to the bits that were first clocked in. Any differences
would point to a fault on that output. If the output was programmed ON by clocking in a zero,
and a one came back as the diagnostic bit for that output, the output pin was still high and a
short circuit or overload condition exists.
If the output was programmed OFF by clocking in a one, and a zero came back as the
diagnostic bit for that output, nothing had pulled the output pin high and it must be floating,
so an open circuit condition exists for that output.