English
Language : 

M24LR64-R_1004 Datasheet, PDF (113/126 Pages) STMicroelectronics – 64 Kbit EEPROM with password protection & dual interface: 400kHz I²C serial bus & ISO 18000-3 mode 1 RF protocol at 13.56MHz
M24LR64-R
I2C DC and AC parameters
Table 104. I2C AC characteristics
Test conditions specified in Table 100
Symbol Alt.
Parameter
Min. Max. Unit
fC
fSCL Clock frequency
400 kHz
tCHCL tHIGH Clock pulse width high
600
ns
tCLCH
tXH1XH2(1)
tXL1XL2(1)
tLOW
tR
tF
Clock pulse width low
Input signal rise time
Input signal fall time
1300
ns
20
300 ns
20
300 ns
tDL1DL2
tF SDA (out) fall time
20
100 ns
tDXCX
tSU:DAT Data in set up time
100
ns
tCLDX
tHD:DAT Data in hold time
0
ns
tCLQX
tCLQV(2)(3)
tCHDX(4)
tDH
tAA
tSU:STA
Data out hold time
Clock low to next data valid (access time)
Start condition set up time
100
ns
100 900 ns
600
ns
tDLCL
tHD:STA Start condition hold time
600
ns
tCHDH
tSU:STO Stop condition set up time
600
ns
tDHDL
tBUF Time between Stop condition and next Start condition 1300
ns
tW
I²C write time
5
ms
1. Values recommended by the I²C-bus Fast-Mode specification.
2. To avoid spurious Start and Stop conditions, a minimum delay is placed between SCL=1 and the falling or
rising edge of SDA.
3. c×tCoLCmQbpVuasisttiibmthleeewctioamnyeswt(aiftrnhotmtihsetlheIes2Csfatslhlpianengc5ief0idc0gaetniosonf(aS(wsChsLipc)ehrcesiqfpiueeidrceiifdniebFsyitgSthUue:rDeSATD4(A)m. binu)s=lin1e00tonrse)a, cahss0u.m8VinCgCtihnaat the Rbus
4. For a reStart condition, or following a write cycle.
Doc ID 15170 Rev 9
113/126