English
Language : 

TDA7476_01 Datasheet, PDF (11/19 Pages) STMicroelectronics – CAR RADIO DIAGNOSTIC PROCESSOR
TDA7476
Figure 3. Timing Diagram on the I2CBUS
SCL
SDA
START
D99AU1032
Figure 4. Acknowledge on the I2CBUS
SCL
1
2
3
7
SDA
START
MSB
D99AU1033
I2CBUS
STOP
8
9
ACKNOWLEDGMENT
FROM RECEIVER
SOFTWARE SPECIFICATIONS
The TDA7476 is activated by turning-on the ST-BY pin (CMOS compatible). In this condition it waits for the
I2CBus addressing byte ADD1 (WRITE to TDA7476)
ADD1
S
010001A
0
ACK
STOP
This sequence (where the bit 0 of ADD1 is at 0 level) enables the acquisition routine and starts the single pulse
(containing infrasonic harmonics) for the test. During this period the data regarding all the outputs are memo-
rized.After a period Twait1 that depends on the value of the timing capacitor (see Timing) the µP redirects the
TDA7476 by the byte ADD2.
ADD1
S
010001A
0
ACK BYTE1 ACK BYTE2 ACK BYTE3 ACK STOP
The byte ADD2 contains the bit 0 at 1 level. This enables the reading mode, TDA7476's. The 3 bytes with the
diagnostic information BYTE1, BYTE2, BYTE3 (READ FROM TDA7476) are now transmitted to the µP.
The address of TDA7476 is selected using pin ADD (pin 4) .
If ADD is connected to ground, then A = 0 and the TDA7476 address is 0100010X.
If ADD is connected to 5V, than A = 1 and the TDA7476 address is 0100011X
s The TDA7476 provides two types of diagnostic information:
A) TURN-ON DIAGNOSTIC - The first time that the TDA7476 is addressed by I2CBus, the more complete set
of diagnostic information is activated:
- CH1, CH2, CH3, CH4, CH5
Short Circuit to GND
Short Circuit to Vs
Open Load (*)
Short Circuit across the load (*)
(*) Detected if the power amplifiers are in ST-BY condition.
- AUX1, AUX2
Short Circuit to GND (*)
Open Load (*)
(*) Detected if the high side drivers attached to the Aux outputs are ON.
Here following the turn-on diagnostic output bytes
11/19