Electrical characteristics
Table 6. Electrical characteristics (DC) (continued)
Symbol
Parameter
Conditions
Min.
Charging start threshold –
VCC_OK VCC undervoltage alarm (VCC_UVLO)
VCC_ASD VCC-VBAT threshold
VCC_OVP VCC overvoltage protection
IODROP_QP Quasi-pulse VCC-VBAT drop
V0V_HD 0V-charge threshold
VPRE_CH
Pre-charge to fast-charge voltage
threshold
±5%
IBAT=100 mA, IBAT=1.0A
±5%
VCC = 5.0 V
ΔVFLT Float voltage range tolerance
VFLT_OVP Float voltage OVP
VFLT = 4.2 V, IBAT =1 mA
TJ = -10 °C to 85 °C
5.0 V < VCC < 9.0 V
TBAT = 0 °C to 60 °C
IBAT = 1.0 mA
TIMER-3 = 60 min.
VCC_QP
Quasi-pulse minimum supply voltage
in pre-charge phase
VBAT_QP
Minimum battery voltage to start
quasi-pulse mode
VRECH Battery recharge threshold voltage
NTC voltage threshold
VTEMP_UN for battery unconnected
5.0 V < VCC < 9.0 V
±2%
NTC voltage threshold
VTEMP_OT for battery overtemperature
±2%
VREF
Reference voltage for NTC /
LED drive voltage
±5%
RDS-ON
TRECH
TFULL
Power MOS saturation resistance 0 °C < TJ < 85 °C
Battery recharge deglitching time
VCC = 5.0 V
Full charge detection deglitching time VCC = 5.0 V – TIMER-3
(after termination)
=0
THV
Battery overvoltage detection
deglitching time
VCC = 5.0 V
THl
Overcurrent detection deglitching
time
VCC = 5.0 V
THOLD_OFF
Deglitching time on VCC to start
charging (VCC=3.0 V)
VBAT = 2.8 V
TBAT_HOT Battery hot detection deglitching time VCC = 5.0 V
TBAT_CON
Battery connection detection
deglitching time
VCC = 5.0 V
TBAT_TLO
Battery TLO temperature detection
deglitching time
VCC = 5.0 V
2.66
8.55
-0.7
4.21
Typ.
2.8
125
9.0
1
3.0
4.23
3.1
2.8
3.9
2.425
0.505
2.9
300
100
100
100
100
10
10
400
100
Max.
2.94
9.45
0.35
0.7
4.25
Unit
V
mV
V
V
V
V
%
V
V
V
V
V
V
V
mΩ
ms
ms
ms
ms
ms
ms
ms
ms
Doc ID 023256 Rev 1