English
Language : 

VND5050J-E_07 Datasheet, PDF (1/37 Pages) STMicroelectronics – Double channel high side driver for automotive applications
VND5050J-E
VND5050K-E
Double channel high side driver
for automotive applications
Features
Max supply voltage
Operating voltage range
Max On-State resistance (per ch.)
Current limitation (typ)
Off state supply current
VCC
VCC
RON
ILIMH
IS
(1) Typical value with all loads connected.
41V
4.5 to 36V
50 mΩ
18 A
2 µA(1)
■ Main
– Inrush current active management by
power limitation
– Very low stand-by current
– 3.0V CMOS compatible input
– Optimized electromagnetic emission
– Very low electromagnetic susceptibility
– In compliance with the 2002/95/EC
European directive
■ Diagnostic functions
– Open drain status output
– On state open load detection
– Off state open load detection
– Thermal shutdown indication
■ Protections
– Undervoltage shut-down
– Overvoltage clamp
– Output stuck to VCC detection
– Load current limitation
– Self limiting of fast thermal transients
– Protection against loss of ground and loss
of VCC
– Thermal shut down
– Reverse battery protection (see Figure 27)
PowerSSO-12
PowerSSO-24
– Electrostatic discharge protection
Application
■ All types of resistive, inductive and capacitive
loads
Description
The VND5050K-E and VND5050J-E are
monolithic devices made using
STMicroelectronics VIPower M0-5 technology.
they are intended for driving resistive or inductive
loads with one side connected to ground. Active
VCC pin voltage clamp protects the devices
against low energy spikes (see ISO7637 transient
compatibility table). The devices detect open load
condition both in on and off state, when STAT_DIS
is left open or driven low. Output shorted to VCC is
detected in the off state. When STAT_DIS is
driven high, STATUS pin is in high impedance
state. Output current limitation protects the
devices in overload condition. In case of long
overload duration, the devices limit the dissipated
power to a safe level up to thermal shut-down
intervention. Thermal shut-down with automatic
restart allows the devices to recover normal
operation as soon as fault conditions disappear..
Table 1. Device summary
Package
PowerSSO-12
PowerSSO-24
Order codes
Part number (Tube)
Part number (Tape & Reel)
VND5050J-E
VND5050JTR-E
VND5050K-E
VND5050KTR-E
December 2007
Rev 4
1/37
www.st.com
37