English
Language : 

TS110-8 Datasheet, PDF (1/10 Pages) STMicroelectronics – High surge voltage 1.25 A SCR for circuit breaker
TS110-8
High surge voltage 1.25 A SCR for circuit breaker
$
*
.
$
*
.
*
60%IODW/
.
*$
72ZLWK ³*$.´ SLQRXW
*$
.
72ZLWK ³.*$´ SLQRXW
Features
• On-state rms current, 1.25 A
• Repetitive peak off-state voltage, 800 V
• Non-repetitive direct surge peak off-state
voltage, 1250 V
• Non-repetitive reverse surge peak off-state
voltage, 900 V
• Triggering gate current, 100 µA
• High off-state immunity: 200 V/µs
• ECOPACK®2 compliant component
Applications
• GFCI (Ground Fault Circuit Interrupter)
• AFCI (Arc Fault Circuit Interrupter)
• RCD (Residual Current Device)
• RCBO (Residual Current circuit Breaker with
Overload protection)
• AFDD (Arc Fault Detection Device)
Datasheet - production data
Description
Thanks to highly sensitive triggering levels, the
TS110-8 series is suitable for circuit breaker
applications where the available gate current is
limited.
The 1250 V direct surge voltage capability of the
TS110-8 enables high robustness of the whole
circuit breaker. The low leakage current of the
TS110-8 reduces power consumption over the
entire lifetime of the circuit breaker. The high
off-state immunity (200 V/µs) insures the non
tripping of the breaker in case of electrical fast
transient (EFT) on the mains.
The TS110-8 is available in through-hole TO-92
package with GAK and KGA pinout and in
SMBflat-3L package.
Table 1. Device summary
Symbol
Value
Unit
IT(RMS)
1.25
A
VDRM, VRRM
800
V
VDSm, VRSM
1250, 900
V
IGT
100
µA
Tj
125
°C
October 2014
This is information on a product in full production.
DocID026589 Rev 1
1/10
www.st.com