English
Language : 

SMTPB Datasheet, PDF (1/5 Pages) STMicroelectronics – TRISILTM
®
SMTPB SERIES
TRISILTM
MAIN APPLICATIONS
Any sensitive equipment requiring protection
against lightning strikes:
ANALOG AND DIGITAL LINE CARDS
MAIN DISTRIBUTION FRAMES
TERMINALS AND TRANSMISSIONEQUIPMENT
GMS-TUBE REPLACEMENT
DESCRIPTION
The SMTPBxx series has been designedto protect
telecommunication equipment against lightning
and transient induced by AC power lines.
FEATURES
BIDIRECTIONAL CROWBAR PROTECTION.
BREAKDOWN VOLTAGE RANGE:
From 62 V To 270 V.
HOLDING CURRENT: IH = 150 mA min
REPETITIVE PEAK PULSE CURRENT :
IPP = 100 A, 10/1000 µs.
BENEFITS
NO AGEING AND NO NOISE
IF DESTROYED, THE SMTPB FALLS INTO
SHORT CIRCUIT, STILL ENSURING
PROTECTION
SMC
SCHEMATIC DIAGRAM
COMPLIES WITH THE
FOLLOWING STANDARDS:
Peak Surge
Voltage
(V)
CCITT K20
4000
VDE0433
4000
VDE0878
4000
IEC-1000-4-5
level 4
level 4
FCC Part 68, lightning surge
type A
1500
800
FCC Part 68, lightning surge
100
type B
BELLCORE TR-NWT-001089
First level
2500
1000
BELLCORE TR-NWT-001089
500
Second level
CNET l31-24
4000
Voltage
Waveform
(µs)
10/700
10/700
1.2/50
10/700
1.2/50
10/160
10/560
5/320
2/10
10/1000
2/10
0.5/700
Current
Waveform
(µs)
5/310
5/310
1/20
5/310
8/20
10/160
10/560
5/320
Admissible
Ipp
(A)
100
100
100
100
100
200
100
25
Necessary
Resistor
(Ω)
-
-
-
-
-
-
-
-
2/10
500
-
10/1000
100
-
2/10
500
-
0.8/310
100
-
August 1999 - Ed: 2C
1/5