English
Language : 

RCD16-47B Datasheet, PDF (1/7 Pages) STMicroelectronics – RCD NETWORK FOR BUS TERMINATION
®
Application Specific Discretes
A.S.D.TM
MAIN APPLICATIONS
In any electronic equipment where a suitable bus
termination is requiredto avoid signal reflectionsand
distortions :
PC and workstation computer
Data-line analyzers
RCD16-47B
RCD NETWORK
FOR BUS TERMINATION
DESCRIPTION
With the increasing speed of data transmission,
line reflections provide signal distorsions and the
overshoots or undershootsproduced on the signal
edges can cause the malfunction of the whole
system.
To avoid these negative effects from leading to
problems, a suitable termination is required.
Dedicated to bus termination, the RCD16-47B
provides by far the best method to minimise stray
emissions from PCB tracks.
SO20
SSOP20
FEATURES
NETWORK OF 16R-C-D LINETERMINATIONS
FUNCTIONAL DIAGRAM
RESISTANCE : R = 47 Ω, TOLERANCE +/- 10%
CAPACITANCE: C = 33 pF, TOLERANCE +/- 10%
1
20
SCHOTTKY DIODE : (D)
2
19
BENEFITS
3
18
Provides impedance matching, thus increasing
4
17
noise immunity and minimizing distortion.
Lowers EMI / RFI radiation.
5
16
No DC power dissipation.
6
15
Eliminates negative voltages : no current will
change the bias of the protected device.
7
14
Uses the best of all termination schemes.
8
13
COMPLIESWITH THE FOLLOWING STANDARDS:
MIL STD 883C - Method 3015-6
- VPP = 2 kV C= 100 pF
R = 1500 Ω
- 3 positive strikes and 3 negativestrikes (F= 1Hz)
9
12
10
11
R = 47 Ω, tolerance +/− 10 %
C = 33 pF, tolerance +/- 10 %
D = Schottky diode
October 1998 - Ed : 2A
1/7