L9662 Datasheet, PDF (1/80 Pages) STMicroelectronics – Octal squib driver and quad Manchester/PSI5 encoded sensor | |||
|
L9662
Octal squib driver and quad Manchester/PSI5 encoded sensor
interface ASIC for safety application
Datasheet - production data
'!0'03
LQFP64 (10x10x1.4mm)
Features
ï· 8 deployment drivers with SPI selectable firing
current and times
ï· Capability to deploy the squib with 1.2 A
(min)/2 ms, 1.75 A (min)/1.0 ms and 1.75 A
(min)/0.65 ms between VRES of 7 V to 37 V
ï· Capability to deploy the squib with 1.5 A
(min)/2 ms between VRES of 7 V to 25 V
ï· Firing capability to deploy all channels
simultaneously
ï· Independently controlled high-side and low-
side MOS for diagnosis
ï· Analog output available for resistance
measurement
ï· Squib short to ground, short to battery and
MOS diagnostic available on SPI register
ï· Capability to deploy the squib the low side
MOS is shorted to ground
ï· 4 Fire enable inputs
ï· Interface with 4 satellite sensors
ï· Programmable independent current trip points
for each satellite channel
ï· Support Manchester 1 or 2 protocol for satellite
sensors
ï· Support PSI5 (Parity) protocol for satellite
sensors (reference PSI5 technical specification
V 1.2 /14.06.07)
ï· Support for Sync pulse and minibus for satellites
ï· Supports for variable bit rate detection
ï· Independent current limit and fault timer
shutdown protection for each satellite output
ï· Short to ground and short to battery detection
and reporting for each satellite channel
ï· 2 independent SPI interfaces
ï· 5.5 MHz SPI interface
ï· Satellite message error detection
ï· Hall effect sensor support on satellite channels
3 and 4.
ï· Low voltage internal reset
ï· 2 kV ESD capability on all pins
ï· Package: LQFP64
ï· Technology: ST Proprietary BCD5
Description
The device is intended to deploy up to 8 squibs
and to interface up to 4 satellites. 2 satellite
interfaces can be used to interface Hall sensors.
Squib drivers are sized to deploy 1.2 A minimum
for 2 ms, 1.75 A minimum for 1 ms and 1.75 A
minimum for 0.65 ms during load dump along with
1.5 A minimum for 2 ms for VRES voltages less
than 25 V.
Full diagnostic capabilities of the squib interface
are provided. Satellite interfaces support
Manchester 1, 2 and PSI5 decoding with variable
bit rate.
Order code
L9662
L9662TR
Table 1. Device summary
Amb. temp range, ï°C
Package
-40 to +85
LQFP64
Packing
Tray
Tape & Reel
September 2015
This is information on a product in full production.
DocID028325 Rev 1
1/80