English
Language : 

ISO8200B Datasheet, PDF (1/33 Pages) STMicroelectronics – Galvanic isolated octal high-side smart power solid state relay
ISO8200B
Galvanic isolated octal high-side smart power solid state relay
Features
Type
Vdemag(1) RDS(on)(1) Iout(1)
Vcc
ISO8200B Vcc- 45 V 0.11 Ω 0.7 A 45 V
1. Per channel
Datasheet − target specification
■ Parallel input interface
■ Direct and synchronous control mode
■ High common mode transient immunity
■ Output current: 0.7 A per channel
■ Short-circuit protection
■ Channel overtemperature protection
■ Thermal independence of separate channels
■ Common output disable pin
■ Case overtemperature protection
■ Loss of GNDcc and Vcc protection
■ Undervoltage shutdown with auto restart and
hysteresis
■ Overvoltage protection (Vcc clamping)
■ Very low supply current
■ Common fault open drain output
■ 5 V and 3.3 V TTL/CMOS compatible I/Os
■ Fast demagnetization of inductive loads
■ Reset function for IC outputs disable
■ ESD protection
Applications
■ Programmable logic control
■ Industrial PC peripheral input/output
■ Numerical control machines
■ Drivers for all types of loads (resistive,
capacitive, inductive)
PowerSO36
Description
The ISO8200B is a galvanic isolated 8-channel
driver featuring a very low supply current. It
contains 2 independent galvanic isolated voltage
domains (Vcc for the power stage and Vdd for the
digital stage). Additional embedded functions are:
loss of GND protection, undervoltage shutdown
with hysteresis, and reset function for immediate
power output shutdown.
The IC is intended to drive any kind of load with
one side connected to ground. Active channel
current limitation combined with thermal
shutdown, (independent for each channel), and
automatic restart, protect the device against
overload and short-circuit. In overload conditions,
if junction temperature overtakes threshold, the
channel involved is turned off and on again
automatically after the IC temperature decreases
below a reset threshold. If this condition causes
case temperature to reach the limit threshold
TCR, the overloaded channel is turned off and
only restarts when case and junction temperature
decrease down to the reset thresholds. Non-
overloaded channels continue to operate
normally. An internal circuit provides an OR-wired
non latched common FAULT indicator signaling
the channel OVT. The FAULT pin is an open drain
active low fault indication pin.
October 2012
Doc ID 023802 Rev 1
This is preliminary information on a new product foreseen to be developed. Details are subject to change without notice.
1/33
www.st.com
33