English
Language : 

BTA08 Datasheet, PDF (1/10 Pages) Sirectifier Global Corp. – Discrete Triacs(Non-Isolated/Isolated)
®
BTA/BTB08 and T8 Series
SNUBBERLESS™, LOGIC LEVEL & STANDARD
8A TRIACS
MAIN FEATURES:
Symbol
Value
Unit
IT(RMS)
8
A
VDRM/VRRM
600 and 800
V
IGT (Q1)
5 to 50
mA
DESCRIPTION
Available either in through-hole or surface-mount
packages, the BTA/BTB08 and T8 triac series is
suitable for general purpose AC switching. They
can be used as an ON/OFF function in
applications such as static relays, heating
regulation, induction motor starting circuits... or for
phase control operation in light dimmers, motor
speed controllers,...
The snubberless versions (BTA/BTB...W and T8
series) are specially recommended for use on
inductive loads, thanks to their high commutation
performances. By using an internal ceramic pad,
the BTA series provides voltage insulated tab
(rated at 2500V RMS) complying with UL
standards (File ref.: E81734)
A2
A2
A2
A1 A2
G
DPAK
(T8-B)
G
A1
A1 A2
G
D2PAK
(T8-G)
A2
A1
A2
G
IPAK
(T8-H)
A2
A1
A2
G
TO-220AB Insulated
(BTA08)
A1
A2
G
TO-220AB
(BTB08)
ABSOLUTE MAXIMUM RATINGS
Symbol
IT(RMS)
ITSM
I²t
dI/dt
IGM
PG(AV)
Tstg
Tj
Parameter
RMS on-state current (full sine wave)
Non repetitive surge peak on-state
current (full cycle, Tj initial = 25°C)
I²t Value for fusing
Critical rate of rise of on-state current
IG = 2 x IGT , tr ≤ 100 ns
Peak gate current
DPAK / D²PAK
IPAK / TO-220AB
TO-220AB Ins.
F = 50 Hz
F = 60 Hz
Tc = 110°C
Tc = 100°C
t = 20 ms
t = 16.7 ms
tp = 10 ms
F = 120 Hz
Tj = 125°C
tp = 20 µs
Tj = 125°C
Average gate power dissipation
Tj = 125°C
Storage junction temperature range
Operating junction temperature range
April 2002 - Ed: 5A
Value
8
80
84
36
50
4
1
- 40 to + 150
- 40 to + 125
Unit
A
A
A²s
A/µs
A
W
°C
1/10