POWER CROSSING
BEHAVIOUR OF LINE CARD PROTECTION
INTRODUCTION
The purpose of this document is to explain the behaviour of LCP 150S/1511/1512 devices during the cou-
pling between a telecommunication line and a mains line.
TEST DIAGRAM
Figure 1 shows the test diagram. The mains 220 V 50 Hz is applied to the test assembly through an iso-
lation transformer. A relay driven by a mono-pulse generator allows the conducting time to be adjusted.
The current through the device is adjusted by a series resistor.
Figure 1. Test Diagram
1/1
220V
50Hz
ISOLATION
TRANSFORMER
RELAY
0 to 4K
Line A
LCPxxx
GND
+
-
POWER SUPPLY
48V
G AT E
MEASUREMENTS
During the tests three kinds of behaviour occur:
a) As shown in Figure 2 the device acts as a clamping device (non-firing) due to the small value of the
current which never exceeds the latching current of the structure.