SDAD101UF_1 Datasheet, PDF (1/1 Pages) Solid States Devices, Inc – ULTRA FAST RECOVERY STACKABLE HIGH VOLTAGE RECTIFIER | |||
|
Solid State Devices, Inc.
14701 Firestone Blvd * La Mirada, CA 90638
Phone: (562) 404-4474 * Fax: (562) 404-1773
ssdi@ssdi-power.com * www.ssdi-power.com
Designerâs Data Sheet
Part Number/Ordering Information 1/
SDAD10 1 __ __ __ __
â
â
â
â
â
â
â
â
â
â
â
â
â
â
â
â
â
â
â
â
â
â
â
â
â
â â Screening 2/
â
__ = Not Screened
â
TX = TX Level
â
TXV = TXV Level
â
S = S Level
â Reverse Recovery Time
â
UF = Ultra Fast Recovery Time
â Voltage 2.5 = 2.5kV, 5 = 5kV,
â
7.5 = 7.5kV, 10 = 10kV, and
â 15 = 15kV
Power Rating (See Below)
â Package Size = 1 Inch Diameter
SDAD101 UF Series
2,500 to 15,000 VOLTS
ULTRA FAST RECOVERY
STACKABLE HIGH VOLTAGE RECTIFIER
FEATURES:
ï· Stackable to 600 kV+
ï· PIV 2.5 kV to 15 kV
ï· Ultra Fast Reverse Recovery Time
ï· Only Hermetically Sealed Rectifiers Used
ï· Controlled Avalanche Rated
ï· Modular Design for Easy Stacking
ï· Storage and Operating Temps -65°C to +150°C
ï· Available in Standard, Fast and Hyper Fast
Versions
ï· TX, TXV, and S-Level Screening Available 2/
ELECTRICAL CHARACTERISTICS 3/
Part Number
SDAD101 H 2.5 UF
SDAD101 H 5.0 UF
SDAD101 H 7.5 UF
SDAD101 H 10 UF
SDAD101 H 15 UF
Peak
Inverse
Voltage
PIV (KV)
25 ï°C
2.5
5.0
7.5
10
15
Reverse
Recovery
Time 5/
Max (ns)
25 ï°C
70
70
70
70
70
Average DC
Output Current
Tc = Case
Temperature 4/
If(avg)
75 ï°C
1.62
0.95
0.81
0.68
0.54
50 ï°C
3.60
2.34
1.80
1.35
0.95
Surge
Maximum
Non-
Forward
repetitive Voltage Drop
Ifsm Vf (V) If (A)
100 ï°C
125
125
125
125
25
25 ï°C
3.96 1.62
6.71 0.95
9.90 0.81
13.0 0.68
18.9 0.54
Maximum
Leakage
Current
@PIV
Ir (uA)
25 ï°C
20
20
20
20
20
SDAD101 Package:
NOTES:
1/ For Ordering Information, Price, Curves, and Availability-
Contact Factory.
2/ Screening based on MIL-PRF-19500. Screening flows available
on request.
3/ Unless Otherwise Specified, All Electrical Characteristics
@25ºC.
4/ Tc = 50 ºC typical operation in oil.
Tc = 75 ºC is typical ambient Ta = 25 ºC unheatsunk.
5/ Recovery Conditions: IF = 0.5 Amp, IR = 1.0 Amp rec. to .25
Amp.
NOTE: All specifications are subject to change without notification.