English
Language : 

SDA138A_1 Datasheet, PDF (1/1 Pages) Solid States Devices, Inc – STANDARD RECOVERY SINGLE PHASE BRIDGE RECTIFIER
Solid State Devices, Inc.
14701 Firestone Blvd * La Mirada, Ca 90638
Phone: (562) 404-4474 * Fax: (562) 404-1773
ssdi@ssdi-power.com * www.ssdi-power.com
Designer’s Data Sheet
Part Number/Ordering Information 1/
SDA138 __ __
│ └ Screening 2/ __ = Not Screened
│
TX = TX Level
│
TXV = TXV
│
S = S Level
│
│ Peak Inverse Voltage
│ A = 50V, B = 100V, C = 200V, D = 400V
└ E = 600V, F = 800V, and G = 1,000V.
SDA138A thru SDA138G
10 AMPS, 50 to 1,000 VOLTS
STANDARD RECOVERY
SINGLE PHASE BRIDGE RECTIFIER
FEATURES:
• Average Output Current 10 Amps @ 55°C
• PIV 50 to 1,000 Volts Per Leg
• Maximum Thermal Resistance 5°C/W
• All Welded Interconnects
• Hermetically Sealed Diode Cells
• Universal 2 Mounting Position Case
• All Machined Aluminum Case
• Available in Fast , Ultra Fast, and Hyper Fast
Versions
ELECTRICAL CHARACTERISTICS 3/
Part Number
Symbol
Uni ts
Conditions
Peak
Inverse
Voltage
(per leg)
Sine Wave
RMS Reverse4/
Input Recovery
Voltage Time
Max.
PIV Vr
Trr
Volts
μs
Max
Average DC Output
Current
TC=Case Temp
IF (AV)
Amps
55°C 100°C 125°C
Average DC
Output Current
TA=Ambient
Temp
(No Heat Sink)
IF (AV)
Amps
55°C 100°C
SDA138A 50 35
SDA138B 100 70
5 10.0 7.0 5.0 1.5 1.0
5 10.0 7.0 5.0 1.5 1.0
SDA138C 200 140
SDA138D 400 280
SDA138E 600 420
5 10.0 7.0 5.0 1.5 1.0
5 10.0 7.0 5.0 1.5 1.0
5 10.0 7.0 5.0 1.5 1.0
SDA138F 800 560
SDA138G 1000 700
5 10.0 7.0 5.0 1.5 1.0
5 10.0 7.0 5.0 1.5 1.0
Peak 1
Cycle
Forward
Surge
IFSM
Amps
100
100
100
100
100
100
100
Peak
Recurrent
Forward
Surge
IFRM
Amps
30
30
30
30
30
30
30
Maximum
Forward
Voltage
Drop (per leg)
@ 3 ADC
VF
Volts
VF
1.1
1.1
1.1
1.1
1.1
1.1
1.1
Reverse
Current
(per leg)
@ PIV
IR
μA
25°C
100°C
2
50
2
50
2
50
2
50
2
50
2
50
2
50
SDA 138A thru SDA138G:
NOTES:
1/ For Ordering Information, Price, Curves, and Availability- Contact
Factory.
2/ Screened to MIL-PRF-19500.
3/ Unless Otherwise Specified, All Electrical Characteristics @25°C.
4/ Recovery Conditions: IF = 0.5 Amp, IR = 1.0 Amp rec. to .25 Amp.
NOTE: All specifications are subject to change without notification.
SCD's for these devices should be reviewed by SSDI prior to release.
DATA SHEET #: RA0075A
DOC