English
Language : 

K16 Datasheet, PDF (2/2 Pages) StarHope – Radial leaded Devices
PPTC/K16 Series
Electrical characteristics(25℃)
Model Ihold
Itrip
Vmax Imax Pd max Maximum Time To Trip
Resistance
Current
Time
Rmin Rmax R1max
(A)
(A)
(Vdc)
(A)
(w)
(A)
(S)
(mΩ)
(mΩ)
(mΩ)
K16-300
3
6
16
100
2.3
9
15
20
60
80
K16-400
4
8
16
100
2.4
12
15
20
40
60
K16-500
5
10
16
100
2.6
15
15
14
25
33
K16-600
6
12
16
100
2.8
18
15
10
21
31
K16-700
7
14
16
100
3.0
21
15
8
15
20
K16-800
8
16
16
100
3.0
24
15
6
13
18
K16-900
9
18
16
100
3.3
27
25
4
12
16
K16-1000 10
20
16
100
3.7
30
30
4
11
15
K16-1100 11
22
16
100
3.7
33
30
3
9
13
K16-1200 12
24
16
100
4.2
36
30
3
8
11
K16-1300 13
26
16
100
4.2
39
50
3
8
11
K16-1400 14
28
16
100
4.2
40
50
3
7
10
Ihold
Itrip
Vmax
Imax
Pd
Rmin/max
R1max
Hold Current:Maximum current device will not trip in 25℃ still air.
Trip current:Minimum current at which the device will always trip in 25℃ still air
Maximum operating volatge device can withstand without damage at ratde current(imax).
Maximum fault current device can withstand without damage at rated voltage(Vmax).
Typical power dissipatde from device when in the tripped state in 25℃ still air.
Minimum/Maximum device resistance prior to tripping at 25℃.
Maximum resistance of device at 25℃ measured one hour after trippde tripping.
*CAUTION Operation beyond the specified rating may result in damage and possible arcing.
Thermal Derating Chart-IH(A)
Part number
-40
-20
Maximum ambidnt operating temperatures(℃)
0
25
40
50
60
70
80
K16-300
4.4
4.0
3.6
3.0
2.6
K16-400
5.9
5.3
4.8
4.0
3.5
2.4
2.1
1.9
1.4
3.2
2.8
2.5
1.9
K16-500
7.3
6.6
6.0
5.0
4.4
4.0
3.6
3.1
2.4
K16-600
8.8
8.0
7.2
6.0
5.2
4.8
4.2
3.8
2.8
K16-700
10.3
9.3
8.4
7.0
6.2
5.6
5.0
4.4
3.3
K16-800
11.7
10.7
9.6
8.0
6.9
6.4
5.6
5.1
3.7
K16-900
13.2
11.9
10.7
9.0
7.9
7.2
6.4
5.6
4.2
K16-1000
14.7
13.3
12.0
10.0
8.7
8.0
7.0
6.3
4.7
K16-1100
16.1
14.6
13.1
11.0
9.7
8.8
7.8
6.9
5.2
K16-1200
17.6
16.0
14.4
12.0
10.4
9.6
8.4
7.6
5.6
K16-1400
20.5
18.7
16.8
14.0
12.1
11.2
9.8
8.9
6.5
Typical Time-To-Trip Curve At 25°C
Thermal Derating Curve
1000
100
10
1
0.1
0.01
1
Average Time Current Curves
10
Current In Amperes
0.75A
0.90A
1.10A
1.35A
1.60A
1.85A
2.50A
3.00A
4.00A
5.00A
6.00A
7.00A
8.060A
9.00A
100
10.0A
11.0A
14.0A
15.0A
16.0A
Derating Curves for K16 Series
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0
-40
-20
0
20
40
60
80
Temperature (C°)
Bulk:
K16-300~800
K16-900
K16-1000~1400
Package Information
1000pcs per bag
500pcs per bag
200pcs per bag
REV.2014.05.01
02 | www.spsemi.cn