English
Language : 

MB9A120L Datasheet, PDF (46/93 Pages) SPANSION – This document states the current technical specifications regarding
DataSheet
Function
group
Power-on reset
or low-voltage
detection state
INITX
input state
Device internal Run mode or
reset state Sleep mode state
Timer mode,
RTC mode, or
Stop mode state
Power supply
unstable
-
-
Power supply stable
INITX = 0
-
INITX = 1
-
Power supply
stable
INITX = 1
-
Power supply stable
INITX = 1
SPL = 0
SPL = 1
GPIO
selected
Maintain previous Maintain previous Hi-Z / Internal input
Setting disabled Setting disabled Setting disabled
state
state
fixed at 0
Sub crystal
F oscillator input
pin /
External sub
Input enabled Input enabled Input enabled Input enabled Input enabled
clock input
selected
Input enabled
GPIO
selected
Maintain previous Maintain previous Hi-Z / Internal input
Setting disabled Setting disabled Setting disabled
state
state
fixed at 0
External sub
clock input
selected
Maintain previous Maintain previous Hi-Z / Internal input
Setting disabled Setting disabled Setting disabled
state
state
fixed at 0
G
Sub crystal
oscillator output
pin
Hi-Z /
Internal input
fixed at 0/
or Input enable
Hi-Z / Internal
input fixed at 0
Hi-Z / Internal
input fixed at 0
Maintain previous Maintain previous
state/When
state/When
Maintain previous oscillation stops*2, oscillation stops*2,
state
Hi-Z / Internal Hi-Z / Internal input
input fixed at 0
fixed at 0
NMIX selected Setting disabled Setting disabled Setting disabled
Maintain previous
state
Resource other
H
than above
selected
GPIO
selected
Maintain previous Maintain previous
Hi-Z /
Hi-Z /
state
Hi-Z
Input enabled Input enabled
state
Hi-Z / Internal input
fixed at 0
JTAG
selected
Pull-up / Input Pull-up / Input
Hi-Z
enabled
enabled
Maintain previous
state
Maintain previous Maintain previous
I
state
state
GPIO
selected
Setting disabled Setting disabled Setting disabled
Hi-Z / Internal input
fixed at 0
March 31, 2015, MB9A120L_DS706-00064-2v0-E
43