6. Low-Voltage Detection Characteristics
(1) Low-Voltage Detection Reset
Parameter Symbol Conditions
(TA = - 40°C to + 85°C)
Min
Value
Typ
Max Unit
Remarks
Detected voltage
VDL SVHR*1 = 00000 1.38
1.50
1.60 V When voltage drops
Released voltage VDH
1.43
1.55
1.65 V When voltage rises
Detected voltage
Released voltage
VDL
VDH
SVHR*1 = 00001
1.43
1.55
1.65
Same as SVHR = 00000 value
V
V
When voltage drops
When voltage rises
Detected voltage
Released voltage
VDL
VDH
SVHR*1 = 00010
1.47
1.60
1.73
Same as SVHR = 00000 value
V
V
When voltage drops
When voltage rises
Detected voltage
Released voltage
VDL
VDH
SVHR*1 = 00011
1.52
1.65
1.78
Same as SVHR = 00000 value
V
V
When voltage drops
When voltage rises
Detected voltage
Released voltage
VDL
VDH
SVHR*1 = 00100
1.56
1.70
1.84
Same as SVHR = 00000 value
V
V
When voltage drops
When voltage rises
Detected voltage
Released voltage
VDL
VDH
SVHR*1 = 00101
1.61
1.75
1.89
Same as SVHR = 00000 value
V
V
When voltage drops
When voltage rises
Detected voltage
Released voltage
VDL SVHR*1 = 00110 1.66
1.80
1.94 V When voltage drops
VDH
Same as SVHR = 00000 value V When voltage rises
Detected voltage
Released voltage
VDL
VDH
SVHR*1 = 00111
1.70
1.85
2.00
Same as SVHR = 00000 value
V
V
When voltage drops
When voltage rises
Detected voltage
Released voltage
VDL
VDH
SVHR*1 = 01000
1.75
1.90
2.05
Same as SVHR = 00000 value
V
V
When voltage drops
When voltage rises
Detected voltage
Released voltage
VDL
VDH
SVHR*1 = 01001
1.79
1.95
2.11
Same as SVHR = 00000 value
V
V
When voltage drops
When voltage rises
Detected voltage
Released voltage
VDL
VDH
SVHR*1 = 01010
1.84
2.00
2.16
Same as SVHR = 00000 value
V
V
When voltage drops
When voltage rises
Detected voltage
Released voltage
VDL
VDH
SVHR*1 = 01011
1.89
2.05
2.21
Same as SVHR = 00000 value
V
V
When voltage drops
When voltage rises
Detected voltage
Released voltage
VDL SVHR*1 = 01100 2.30
2.50
2.70 V When voltage drops
VDH
Same as SVHR = 00000 value V When voltage rises
Detected voltage
Released voltage
VDL
VDH
SVHR*1 = 01101
2.39
2.60
2.81
Same as SVHR = 00000 value
V
V
When voltage drops
When voltage rises
Detected voltage
Released voltage
VDL
VDH
SVHR*1 = 01110
2.48
2.70
2.92
Same as SVHR = 00000 value
V
V
When voltage drops
When voltage rises
Detected voltage
Released voltage
VDL
VDH
SVHR*1 = 01111
2.58
2.80
3.02
Same as SVHR = 00000 value
V
V
When voltage drops
When voltage rises
Detected voltage
Released voltage
VDL SVHR*1 = 10000 2.67
2.90
3.13 V When voltage drops
VDH
Same as SVHR = 00000 value V When voltage rises
Detected voltage
Released voltage
VDL SVHR*1 = 10001 2.76
3.00
3.24 V When voltage drops
VDH
Same as SVHR = 00000 value V When voltage rises
Detected voltage
Released voltage
VDL SVHR*1 = 10010 2.85
3.10
3.35 V When voltage drops
VDH
Same as SVHR = 00000 value V When voltage rises
Detected voltage
Released voltage
VDL
VDH
SVHR*1 = 10011
2.94
3.20
3.46
Same as SVHR = 00000 value
V
V
When voltage drops
When voltage rises
LVD stabilization
wait time
tLVDW
-
-
-
5200 ×
tCYCP*2
μs
LVD detection
delay time
tLVDDL
-
-
-
200 μs
*1: The SVHR bit of Low-Voltage Detection Voltage Control Register (LVD_CTL) is initialized to 00000 by
Low-Voltage Detection Reset.
*2: tCYCP indicates the APB2 bus clock cycle time.
112