ICX274AL Datasheet, PDF (9/71 Pages) Sony Corporation – Diagonal 8.923mm (Type 1/1.8) Progressive Scan CCD Image Sensor with Square Pixel for B/W Video Cameras | |||
|
◁ |
ICX274AL
(3) Horizontal transfer clock waveform
tr
twh
tf
HÏ2β
90%
10%
HÏ1β
VÏH
VÏH
2
two
VCR
twl
VHL
Cross-point voltage for the HÏ1β rising side of the horizontal transfer clocks HÏ1β and HÏ2β waveforms is VCR.
The overlap period for twh and twl of horizontal transfer clocks HÏ1β and HÏ2β is two. (β = A, B)
(4) Reset gate clock waveform
tr
twh
tf
RG waveform
VRGH
VRGLH
VRGLL
VRGLm
VÏRG
twl
Point A
VRGL
VRGLH is the maximum value and VRGLL is the minimum value of the coupling waveform during the period from
Point A in the above diagram until the rising edge of RG.
In addition, VRGL is the average value of VRGLH and VRGLL.
VRGL = (VRGLH + VRGLL)/2
Assuming VRGH is the minimum value during the interval twh, then:
VÏRG = VRGH â VRGL
Negative overshoot level during the falling edge of RG is VRGLm.
(5) Substrate clock waveform
100%
90%
10%
VSUB
0%
(Internally generated bias)
VÏSUB
tr
twh
tf
â9â
ÏM
ÏM
2
|
▷ |