English
Language : 

ICX267AK Datasheet, PDF (8/29 Pages) Sony Corporation – Diagonal 8mm (Type 1/2) Progressive Scan CCD Image Sensor with Square Pixel for Color Cameras
ICX267AK
Clock Switching Characteristics
Item
twh
twl
tr
tf
Symbol
Unit Remarks
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max.
Readout clock
VT
3.2 3.4
0.5
0.5
µs
During
readout
Vertical transfer
clock
Vφ1, Vφ2A,
Vφ2B, Vφ3
15
450 ns ∗1
During
Hφ1
imaging
Hφ2
10 12.5
10 12.5
10 12.5
10 12.5
5 7.5
5 7.5
5 7.5
ns ∗2
5 7.5
During
Hφ1
parallel-serial
conversion Hφ2
0.01
0.01
µs
0.01
0.01
Reset gate clock φRG
48
24
2
2
ns
Substrate clock φSUB
3.9
0.5
0.5
µs
During drain
charge
∗1 When vertical transfer clock driver CXD1267AN × 2 is used.
∗2 tf ≥ tr – 2ns, and the cross-point voltage (VCR) for the Hφ1 rising side of the Hφ1 and Hφ2 waveforms must
be at least VφH/2 [V].
Item
Horizontal transfer clock
Symbol
Hφ1, Hφ2
two
Unit Remarks
Min. Typ. Max.
8 10
ns
Spectral Sensitivity Characteristics (excludes lens characteristics and light source characteristics)
1.0
0.8
0.6
0.4
0.2
0
400
500
600
700
800
900
1000
Wave Length [nm]
–8–