1. Drive mode data
(1) Drive mode setting
The CXD3607R drive mode can be switched as follows.
â TRIGOUT mode is the mode which stops the SG pulse (ternary value output of the V2A and V2B pulses)
and the corresponding V pulse of FINE mode. Note that this is different from the special drive data âSG
stop settingâ.
D1 D0 Description of operation
0
0 DRAFT mode
0
1 FINE mode
1
X TRIGOUT mode
(2) TRIG function setting (valid in DRAFT, FINE and TRIGOUT modes)
The CXD3607R random trigger shutter function disabled/enabled setting can be switched as follows.
â For details, see âSpecial Drive Sequence (Random trigger shutter drive)â.
D2
Description of operation
0 TRIG function disabled
1 TRIG function enabled
2. Special drive data
(1) SG stop setting (valid in DRAFT and FINE modes)
SG pulse (ternary value output of the V2A and V2B pulses) stopped/not stopped can be selected by the
D0 setting.
â When SG stopped is selected, the corresponding V pulse is not stopped.
â When SG stopped is selected, WEN becomes inactive during that VD period.
D0
Description of operation
0 SG not stopped
1 SG stopped
(2) SUB pulse stop setting (valid in DRAFT, FINE and TRIGOUT modes)
SUB pulse stopped/not stopped can be selected by the D1 setting.
D1
Description of operation
0 SUB not stopped
1 SUB stopped