SN8P2610 Datasheet, PDF (20/102 Pages) SONiX Technology Company – 8-Bit Micro-Controller | |||
|
◁ |
SN8P2610 Series
8-Bit Micro-Controller
¾ Example: â@JMP_Aâ application in SONIX macro file called âMACRO3.Hâ.
B0MOV
@JMP_A
JMP
JMP
JMP
JMP
JMP
A, BUF0
5
A0POINT
A1POINT
A2POINT
A3POINT
A4POINT
; âBUF0â is from 0 to 4.
; The number of the jump table listing is five.
; ACC = 0, jump to A0POINT
; ACC = 1, jump to A1POINT
; ACC = 2, jump to A2POINT
; ACC = 3, jump to A3POINT
; ACC = 4, jump to A4POINT
If the jump table position is across a ROM boundary (0x00FF~0x0100), the â@JMP_Aâ macro will adjust the jump table
routine begin from next RAM boundary (0x0100).
¾ Example: â@JMP_Aâ operation.
; Before compiling program.
ROM address
0X00FD
0X00FE
0X00FF
0X0100
0X0101
B0MOV
@JMP_A
JMP
JMP
JMP
JMP
JMP
A, BUF0
5
A0POINT
A1POINT
A2POINT
A3POINT
A4POINT
; âBUF0â is from 0 to 4.
; The number of the jump table listing is five.
; ACC = 0, jump to A0POINT
; ACC = 1, jump to A1POINT
; ACC = 2, jump to A2POINT
; ACC = 3, jump to A3POINT
; ACC = 4, jump to A4POINT
; After compiling program.
ROM address
0X0100
0X0101
0X0102
0X0103
0X0104
B0MOV
@JMP_A
JMP
JMP
JMP
JMP
JMP
A, BUF0
5
A0POINT
A1POINT
A2POINT
A3POINT
A4POINT
; âBUF0â is from 0 to 4.
; The number of the jump table listing is five.
; ACC = 0, jump to A0POINT
; ACC = 1, jump to A1POINT
; ACC = 2, jump to A2POINT
; ACC = 3, jump to A3POINT
; ACC = 4, jump to A4POINT
SONiX TECHNOLOGY CO., LTD
Page 20
Version 1.3
|
▷ |