Specifications
Compatt 5 Wideband Transponder - Heavy Load
Feature
Type 8045
Type 8047
Depth Rating
7,000 Metres
7,000 Metres
Frequency
MF (18–36kHz)
MF (18–36kHz)
Transducer Beamshape
Omni-Directional
Directional
Operating Range (from surface/ROV)
2,000 Metres
7,000 Metres
Transmit Source Level (dB re 1µPa @ 1m)
185-192dB (Three Levels)
195-202dB (Three Levels)
Receive Threshold (dB re 1µPa)
90-120dB (Four Levels)
90-120dB (Four Levels)
Relative Positioning Accuracy (with Wideband) 0.05-1.0 m
0.05-1.0 m
Number of Unique Addresses (Wideband)
224
224
Number of Unique Addresses (Tone)
All Sonardyne/Simrad
All Sonardyne/Simrad
Battery Life (Listening, Disabled) Std. Housing 833 days (Alkaline) 1389 (Lithium) 833 days (Alkaline) 1389 (Lithium)
Short Housing 417 (Lithium Option Only)
417 (Lithium Option Only)
Safe Working Load (4:1)
2,500kg
2,500kg
Release Load
2,500kg
2,500kg
Breaking Load
10,000kg
10,000kg
Mechanical Construction
Ferralium 255
Ferralium 255
Dimensions (LxDia)
Std. Housing 868mm (34.2”) x 145mm (5.7”) 868mm (34.2”) x 145mm (5.7”)
Short Housing 814mm (32”) x (145mm (5.7”) 814mm (32”) x (145mm (5.7”)
Weight in Air
TBA
TBA
Weight in Water
Endcap Sensors (Fitted as Standard)
TBA
TBA
Temperature (PRT) , Tilt Switch (± 30-45º), Depth (strain Gauge Pressure
transducer), Power for external sensors
Definitions
Safe Working Load – The maximum
recommended working load. This is set as a
quarter (1/4) of the Breaking Load and makes
an allowance for factors such as corrosion,
fatigue and dynamic loads
Release Load – The maximum in-line load that
the whole assembly can release whilst
guaranteeing safe and reliable operation.
Breaking Load – The load that induces
structural failure in one or more parts of the
instrument causing the load to part from the
release mechanism.
Operating Range – The operational range of
the Heavy Load Compatt is dependant on the
nature of the interrogating transceiver and the
noise environment the system is operating in
Specifications subject to change without notice - 10/2006