Electrical Rating
Item
DC Spark-over Voltage
Impulse Spark-over
Voltage
Insulation Resistance
Capacitance
Nominal Impulse
Discharge Current
Test Condition / Description
Requirement
The voltage is measured with a slowly rate of rise dv / dt=100V/s
The maximum impulse spark-over voltage is measured with a rise time of
dv / dt=100V//μs or 1KV/μs
The resistance of gas tube shall be measured each terminal each other terminal,
please see above spec.
The capacitance of gas tube shall be measured each terminal to each other
terminal.
Test frequency :1MHz
The maximum current applying a waveform of 8/20μs that can be applied across
the terminals of the gas tube. One hour after the test is completed, re-testing of the
DC spark-over voltage does not exceed ±30% of the nominal DC spark-over
voltage. Dwell time between pulses is 3 minutes.
To meet
the specified
value
Nominal Alternating
Discharge Current
Rated RMS value of AC current at 50Hz, 1 sec. 10 times. Intervals: 3min. The DC
spark-over voltage does not exceed ±30% of the nominal DC spark-over voltage.
IR > 108ohms.
Recommended soldering profile
Wave soldering
Reflow soldering
Soldering profile applied a single process
Soldering Parameters - Hand Soldering
Solder Iron Temperature: 350°C +/-5°C
Heating Time: 5 seconds max.
SOCAY Electronics Co., Ltd.
Revision October 18, 2013
4/6
www.socay.com
@SOCAY Electronics Co., Ltd. 2013
Specifications are subject to change without notice.