English
Language : 

SC30-040 Datasheet, PDF (4/4 Pages) Socay Electornics Co., Ltd. – Radial Lead Resettable Polymer PTCs
Radial Lead Resettable Polymer PTCs
SC30 Series
Dimensions
Part
Number
SC30-040
SC30-050
SC30-065
SC30-075
SC30-090
SC30-110
SC30-135
SC30-160
SC30-185
SC30-250
SC30-300
SC30-400
SC30-500
SC30-600
SC30-700
SC30-800
SC30-900
Figure1
Figure
Figure1
Figure1
Figure1
Figure1
Figure2
Figure2
Figure2
Figure2
Figure2
Figure2
Figure3
Figure3
Figure3
Figure3
Figure3
Figure3
Figure3
A
Inches mm
Max. Max.
0.236
6.0
0.236
6.0
0.276
7.0
0.283
7.2
0.276
7.0
0.256
6.5
0.346
8.8
0.346
8.8
0.394 10.0
0.445 11.3
0.445 11.3
0.531 13.5
0.570 14.5
0.630 16.0
0.728 18.5
0.827 21.0
0.965 24.5
B
Inches mm
Max. Max.
0.445 11.3
0.472 12.0
0.472 12.0
0.480 12.2
0.472 12.0
0.571 14.5
0.543 13.8
0.610 15.5
0.630 16.0
0.728 18.5
0.669 17.0
0.700 17.8
0.925 23.5
0.925 23.5
0.965 24.5
1.102 28.0
1.102 28.0
Figure2
C
Inches mm
Typ.
Typ.
0.200
5.1
0.200
5.1
0.200
5.1
0.200
5.1
0.200
5.1
0.200
5.1
0.200
5.1
0.200
5.1
0.200
5.1
0.200
5.1
0.200
5.1
0.200
5.1
0.400 10.2
0.400 10.2
0.400 10.2
0.400 10.2
0.400 10.2
D
Inches mm
Max. Max.
0.118
3.0
0.118
3.0
0.118
3.0
0.118
3.0
0.118
3.0
0.118
3.0
0.118
3.0
0.118
3.0
0.118
3.0
0.118
3.0
0.118
3.0
0.118
3.0
0.118
3.0
0.118
3.0
0.118
3.0
0.118
3.0
0.118
3.0
Figure3
Lead (dia)
Inches Mm
0.020
0.5
0.020
0.5
0.020
0.5
0.020
0.5
0.020
0.5
0.020
0.5
0.020
0.5
0.020
0.5
0.020
0.5
0.020
0.5
0.031
0.8
0.031
0.8
0.031
0.8
0.031
0.8
0.031
0.8
0.031
0.8
0.031
0.8
Packaging
(Bulk Pack)
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
500
500
500
200
200
200
Warning
u This product should not be used in an application where the maximum interrupt voltage or maximum interrupt current in a fault
condition, Operation beyond the maximum rating or improper use may result in device damage and possible electrical arcing
and flame.
u A PPTC device is not a fuse, It is a nonlinear thermistor that limits current, Because under a fault condition all PPTC devices
go into a high resistance state but not open circuit hazardous voltage may be present at PPTC.
u The devices are intended for protection against occasional over-current or over-temperature fault conditions and should not
be used when repeated fault conditions or prolonged trip events.
u In most application, power must be removed and the fault condition cleared in order to reset a PPTC device.
u PPTC devices are not recommended to be installed in applications where the device is constrained such that its PPTC
properties are inhibited, for example in rigid potting materials or Add devices surface coating, Bundled devices ontology,
which lack adequate clearance to accommodate device expansion.
u Contamination on of the PPTC material with certain silicone-based oils or some aggressive solvents can adversely impact the
performance of the devices. For example, Organic solvents to cleaning.
SOCAY Electronics Co., Ltd.
Revision September 12, 2013
4/4
www.socay.com
@ SOCAY Electronics Co., Ltd. 2013
Specifications are subject to change without notice.
Please refer to www.socay.com for current information.