English
Language : 

EMC6D102_07 Datasheet, PDF (50/86 Pages) SMSC Corporation – Fan Control Device with Hardware Monitoring and Acoustic Noise Reduction Features
Fan Control Device with Hardware Monitoring and Acoustic Noise Reduction Features
Datasheet
TEMPERATURE
-127°c
.
.
.
-50°c
.
.
.
0°c
.
.
.
50°c
.
.
.
127°c
(SENSOR ERROR)
Table 7.3 Temperature vs. Register Reading
READING (DEC)
-127
.
.
.
-50
.
.
.
0
.
.
.
50
.
.
.
127
READING (HEX)
81h
.
.
.
CEh
.
.
.
00h
.
.
.
32h
.
.
.
7Fh
80h
7.2.5
Registers 28-2Fh: Fan Tachometer Reading
Register
Address
28h
29h
2Ah
2Bh
2Ch
2Dh
2Eh
2Fh
Read/
Write
R
R
R
R
R
R
R
R
Register Name
Tach1 LSB
Tach1 MSB
Tach2 LSB
Tach2 MSB
Tach3 LSB
Tach3 MSB
Tach4 LSB
Tach4 MSB
Bit 7
(MSb)
7
15
7
15
7
15
7
15
Bit 6
6
14
6
14
6
14
6
14
Bit 5
5
13
5
13
5
13
5
13
Bit 4 Bit 3 Bit 2
4
3
2
12
11
10
4
3
2
12
11
10
4
3
2
12
11
10
4
3
2
12
11
10
Bit 1
1
9
1
9
1
9
1
9
Bit 0
(LSb)
0
8
0
8
0
8
0
8
Default
Value
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
The Fan Tachometer Reading registers contain the number of 11.111μs periods (90KHz) between full
fan revolutions. Fans produce two tachometer pulses per full revolution. These registers are updated
at least once every second.
This value is represented for each fan in a 16 bit, unsigned number.
The Fan Tachometer Reading registers always return an accurate fan tachometer measurement, even
when a fan is disabled or non-functional, including when the start bit=0.
When one byte of a 16-bit register is read, the other byte latches the current value until it is read, in
order to ensure a valid reading. The order is LSB first, MSB second.
FFFFh indicates that the fan is not spinning, or the tachometer input is not connected to a valid signal
(This could be triggered by a counter overflow).
These registers are read only – a write to these registers has no effect.
Revision 0.4 (09-25-07)
50
DATASHEET
SMSC EMC6D102