English
Language : 

GPMP600 Datasheet, PDF (7/12 Pages) SL Power Electronics – ENVIRONMENTAL REPORT: EXECUTIVE SUMMARY
Condor Temperature HALT Profile
100
90
80
70
60
50
40
30
Temp
20
Power
10
0
-10
-20
-30
-40
-50
0
2
4
6
8
10
12
14
16
18
20
Time (Hrs.)
Power Cycling: Five OFF/ON cycles (1 Min ON / 1 Min OFF) are performed at the end of each dwell.
Parameters monitored: Vin, Vout, signals as required (power good, etc.)
Pass/Fail criteria: Loss of output, or output is outside specified limit.
Random Vibration Step Stress
Level
Time Overall
(min:sec) Grms
PSD Gsqd/Hz
Cum.
10 Hz
350 Hz
2000 Hz
Damage
(Qual=1)
1
10:00
5
0.038
0.038
0.0012
0.17
2
10:00
7
0.078
0.078
0.0024
1.6
3
10:00
9
0.129
0.129
0.004
9
4
10:00
11
0.192
0.192
0.0059
37
5
10:00
13
0.269
0.269
0.0082
120
Parameters Monitored: Vin, Vout, signals as required (power good, etc.)
Pass/Fail criteria: Loss of output, or output is outside specified limit.
Condor HALT Random Vibration Profile
1
.1
.01
.001
.0001
10
100
Frequency (Hz)
1000 2000
X Axis
Z Axis