English
Language : 

XPFM200 Datasheet, PDF (2/2 Pages) SL Power Electronics – XPFM200A+ Medical Power Supply
Model
XPFM200A+
Output No.
1(C)
Output
+3.3 V
Minimum
Current
0.1 A
Maximum
Current
14 A
Peak (E)
Current
16 A
Total Regulation
±4%
OVP
Trip
4 V± 0.3 V
Ripple and
Noise
2%
Notes
D
2 (C)
+5.1 V
1A
22 A
28 A
±4%
6.2 V 0.5 V
1%
3 (A)
+12 V
0.1 A
7A
9A
±5%
1%
4 (B)
-12 V
0A
0.8 A
0.8 A
±8%
1%
5
-5 V
0A
0.5 A
0.5 A
±6%
1%
6 (E)
+5 VSB
0A
1.5 A
--
±4%
6.2 V ±0.8 V
2%
XPFM200B+
1 (C)
+2.7 V
0.1 A
14 A
16 A
±4%
4 V± 0.3 V
2%
D
2 (C)
+5 V
1A
22 A
28 A
±4%
6.2 V 0.5 V
1%
3 (A)
+12 V
0.1 A
7A
9A
±5%
1%
4 (B)
-12 V
0A
0.8 A
0.8 A
±8%
1%
5
-5 V
0A
0.5 A
0.5 A
±6%
1%
6 (E)
+5 VSB
0A
1.5 A
--
±4%
6.2 V ±0.8 V
2%
A. To maintain regulation on V3, the +5.1 V current must be at least 1/5 of V3 and not greater than 5 times the V3 current. Required +5 V to be adjusted
to within ±1% with at least a 1 A load to maintain regulation on this output.
B. Combined current of V4, 5 must not exceed 0.8 A.
C. Combined load for V1, 2 must not exceed 125 W.
D. 200 Series has external fan, for internal fan replace 200 in model number with 201.
E. V6 maximum current is 1.25 A at initial start up.
XPFM200+ MECHANICAL SPECIFICATIONS:
XPFM200
External Fan
XPFM201
Internal Fan
Environmental
Specification
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
Operating
0 to 40ºC
0 to 95% RH
20 g
pk
-500 to 10,000 ft
1.5 grms, 0.003 g2/Hz
Non-operating
-40 to +85ºC
0 to 95% RH
40 g
pk
-500 to 40,000 ft
5 grms, 0.026
g2/Hz
A. Units should be allowed to warm up/operate under non-condensing conditions
before application of power. Cooling provided by internal fan— heatsink
temperatures should not exceed 90ºC for extended periods in the installation.
B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,
total 6 shocks.
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com
111