English
Language : 

GPFM115 Datasheet, PDF (2/2 Pages) SL Power Electronics – 115 Watt Global Performance Switchers
Medical
Model
GPFM115-5
GPFM115-12
GPFM115-13
GPFM115-15
GPFM115-24
GPFM115-28
GPFM115-48
RoHS
Suffix*
G
G
G
G
G
G
G
Voltage
Output
5.1 V
12 V
13 V
15 V
24 V
28 V
48 V
Output Ad-
justment
±5%
±5%
±5%
±5%
±5%
±5%
±5%
Output
Maximum (A)
12 A
6.7 A
6.2 A
5.3 A
3.3 A
2.9 A
1.7 A
Maximum (B)
20 A
9.6 A
8.8 A
7.7 A
4.8 A
4.1 A
2.4 A
Output Peak
25 A
10.8 A
9.9 A
8.7 A
5.4 A
4.6 A
2.7A
Total
Regulation
2%
2%
2%
2%
2%
2%
2%
OVP
Setpoint
6.2 ± 0.6 V
14 ± 1.1 V
15 ± 1.1 V
18.5 ± 1.5 V
28 ± 2.5 V
34 ± 2.8 V
55 ± 4.0 V
Ripple/
Noise
1%
1%
1%
1%
1%
1%
1%
Notes:
* Add “G” suffix to part number for RoHS compliant model.
A. Maximum continuous current rating for unrestricted convection cooling.
B. Maximum continuous current rating with 150 LFM air or cover option.
C. Add “-C” after voltage in model number for cover with fan option.
Notes
C
C
C
C
C
C
C
GPFM115 MECHANICAL SPECIFICATIONS
JI INPUT: (AMP P.C.B. HEADER P.N 640445-5)
PIN 1) AC LINE
PIN 2) = N/C
PIN 3) = AC NEUTRAL
PIN 4) = N/C
PIN 5) = AC GROUND
SIGNALS: J2
AMP P.C.B. HEADER P/N 640456-4
MATING CONNECTOR P/N 640621-4
PIN 1) POWER FAIL
PIN 2) -SENSE
PIN 3) +SENSE
PIN 4) COMMON
FAN: J4
AMP P.C.B. HEADER P/N 640456-2
MATING CONNECTOR P/N 640621-2
PIN 1) -
PIN 2) +
OUTPUT
J3- 5A MAXIMUM CONTINUOUS CURRENT PER
CONNECTOR PIN.
AMP P.C.B. HEADER P/N 640445-8
PIN 1-4) +Vout
PINS 5-8) RETURN
OUTPUT-MATING CONNECTOR AMP P/N
HOUSING 640250-8
CONTACT 770476-1
INPUT MATING CONNECTOR AMP P/N
HOUSING 640250-5
CONTACT 770476-1
MAX. SCREW PROTRUSION THROUGH CHASSIS = 0.08”
[2 MM], CHASSIS THICKNESS = 0.080” [2 MM]
OPTIONAL COVER/FAN ASSEMBLY
AVAILABLE P/N 09-115CF
ENVIRONMENTAL SPECIFICATIONS
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
OPERATING
0 to 50°
0 to 95% RH
20 gpk
-500 to 10,000 ft
1.5 g rms’ 0.003 g2/Hz
NON-OPERATING
-40 to +85°C
0 to 95% RH
40 gpk
-500 to 40,000 ft
5 g rms’ 0.026 g2/Hz
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power. Derate output current and total
output power by 2.5% per °C above 50°C. For operation in a confined
space, moving air may be required. Under all conditions, the cooling vs.
load profile should be such that chassis temperatures do not exceed
90°C for extended periods.
B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3
orthogonal axes, total 6 shocks.
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1
hr./axis non-operating.
SL Power Electronics, Inc. 6050 King Drive, Bldg. A, Ventura, CA, 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: info@slpower.com www.slpower.com Rev.
5/6/08. Data Sheet © 2008 SL Power Electronics, Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.