English
Language : 

GPFC250 Datasheet, PDF (2/2 Pages) SL Power Electronics – 250 Watt Global Performance Switchers
Commercial
Model
Medical
Model
RoHS
Suffix* Output No.
Output
Voltage
Output
Output
Adjustment Maximum (A) Maximum (B)
GPFC250-3.3 GPFM250-3.3
G
1
3.3 V
±5%
36 A
50 A
GPFC250-5 GPFM250-5
G
1
5.1 V
±5%
36 A
50 A
GPFC250-12 GPFM250-12
G
1
12 V
±5%
15 A
21 A
GPFC250-15 GPFM250-15
G
1
15 V
±5%
12 A
16.7 A
GPFC250-24 GPFM250-24
G
1
24 V
±5%
7.5 A
10.5 A
GPFC250-28 GPFM250-28
G
1
28 V
±5%
6.5 A
9A
GPFC250-48 GPFM250-48
G
1
48 V
±5%
3.8 A
5.3 A
* Add “G” suffix to part number for RoHS compliant model.
A. Continuous output rating with unrestricted convection cooling.
B. Continuous output rating with 26cfm airflow or “-C” option. Also one minute peak rating for convection cooled.
C. Add “-C” suffix for factory installed cover with fan option.
OVP Setpoint
6.2 ± 0.6 V
6.2 ± 0.6 V
14 ± 1.1 V
18.5 ± 1.5 V
28 ± 2.5 V
34 ± 2.8 V
55 ± 4.0 V
Total
Regulation
2%
2%
2%
2%
2%
2%
2%
GPFC250/GPFM250 MECHANICAL SPECIFICATIONS
INPUT:
TB1
6-32, 3 PIN TERMINAL BLOCK 0.375”
PIN 1) AC LINE
PIN 2) AC NEUTRAL
PIN 3) AC GROUND
SIGNALS: J2
AMP P.C.B. HEADER P/N 640456-5
MATING CONNECTOR P/N640440-5
PIN 1) DC GOOD
PIN 2) POWER FAIL
PIN 3) EXT OFF
PIN 4) +SENSE
PIN 5) -SENSE
FAN
AMP P.C.B. HEADER P/N 640456-2
MATING CONNECTOR P/N 640440-2
PIN 1) -
PIN 2) +
OUTPUT:
TB2
6-32, 4 PIN TERMINAL BLOCK 0.375
[9.53mm]CTR
AN OPTIONAL BUS BAR WITH 10-32
SCREWS ON HIGH-CURRENT MODELS
IS AVAILABLE BY ADDING -B TO
MODEL NUMBER
PINS 1-2) +Vout
PINS 3-4) RETURN
16A MAXIMUM RECOMMENDED
CURRENT PER CONNECTOR PIN.
MAX. SCREW PROTRUSION ABOVE
CHASSIS =0.120” [3.05MM].
OPTIONAL: COVER/FAN ASSEMBLY #09-250CF
CAN BE INCLUDED BY ADDING -C TO
MODEL NUMBER
WEIGHT: 2.9 LBS. [1.32 kg] MAX.
TOLERANCES: X.XX=0.030 [0.76mm]
X.XXX+0.010 [0.25 mm]
Notes
C
C
C
C
C
C
C
ENVIRONMENTAL SPECIFICATIONS
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
OPERATING
0 to 50°
0 to 95% RH
20 gpk
-500 to 10,000 ft
1.5 g rms’ 0.003 g2/Hz
NON-OPERATING
-40 to +85°C
0 to 95% RH
40 gpk
-500 to 40,000 ft
5 g rms’ 0.026 g2/Hz
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power. Derate output current and total
output power by 2.5% per °C above 50°C.
B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3
orthogonal axes, total 6 shocks.
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1
hr./axis non-operating.
SL Power Electronics Corp., 6050 King Drive, Bldg. A, Ventura, CA, 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: info@slpower.com Rev. 4/9/07.
Data Sheet © 2006 SL Power Electronics Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.